INTELIA 04 OPERATING LOGIC
Saeco International Group
Rev. 02 / September 2012
Page / 08
Notes: * Only with Pre-brewing
4.2.
Coffee
cycle
Switching on
When the machine is switched on, the gear motor repositions itself as follows:
- It acts on microswitch 1 (see following chapter).
- The gear motor changes its rotation direction and moves upwards again by approx. 1-2 mm.
- The boiler begins to heat the water for approx. 45 sec., at full power, in order to reach the
optimal temperature. The temperature will then remain at a constant level.
Coffee cycle
The coffee grinder starts the grinding process (controlled by pulses generated by a sensor).
1.
The gear motor (brewing unit) moves to the brewing position.
2.
Preliminary dispensing phase (short pump activity, short pause).
3.
Product dispensing (the pump operation period is de
fi
ned by the amount of product dis-
4.
pensed).
The gear motor moves to its home position (the dregs are expelled automatically).
5.
Main switch ON
START
STOP
Time
Coffee grinder
Heating
Pump
Brewing unit gear
motor
Status
Heating
Ready
Coffee cycle
Pulses
(Dosage)
Pump operation (
fl
ow
meter pulses) in
accordance with the
amount of product
selected.
approx.
45 sec.
*
03
Single microswitch gear motor
Status
Microswitch
OFF
ON
Summary of Contents for Intelia
Page 3: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 1 INTRODUCTION...
Page 9: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 3 USER INSTRUCTIONS...
Page 24: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 4 OPERATING LOGIC...
Page 33: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 5 TROUBLESHOOTING...
Page 56: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 6 STANDARD CHECKS...
Page 59: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 7 DISASSEMBLY...
Page 71: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 8 NOTES...
Page 72: ...INTELIA 08 NOTES Saeco International Group Rev 02 September 2012 Page 01 01...
Page 73: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 76: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM...