INTELIA 05 TROUBLESHOOTING
Saeco International Group
Rev. 02 / September 2012
Page / 22
Operational check – brewing unit
When the unit is in position, the WORK indication changes from “N” to “Y”,
When the unit is in position, the WORK indication changes from “N” to “Y”,
the absorption current must be less than 200mA without the brewing unit
the absorption current must be less than 200mA without the brewing unit
on, and less than 300mA with the brewing unit on.
on, and less than 300mA with the brewing unit on.
ERROR condition:
ERROR condition:
The WORK indicator always stays on “N”
The WORK indicator always stays on “N”
ERROR:
ERROR:
The WORK indicator changes, and remains permanently on “N”, while the
The WORK indicator changes, and remains permanently on “N”, while the
display changes from green to red; check the microswitch, the motor of the
display changes from green to red; check the microswitch, the motor of the
gear motor (this may be blocked) and the wiring JP16.
gear motor (this may be blocked) and the wiring JP16.
ERROR (without brewing unit):
ERROR (without brewing unit):
If the absorbed current exceeds 200 mA the display turns red, check the
If the absorbed current exceeds 200 mA the display turns red, check the
gears on the gear motor and the motor housing in its seat.
gears on the gear motor and the motor housing in its seat.
Initial status
Initial status
IMPORTANT: This check can only be carried out with the dreg drawer in
IMPORTANT: This check can only be carried out with the dreg drawer in
and the side hatch closed
and the side hatch closed
Press the espresso button to move the brewing unit to the “WORK” position
ERROR (with brewing unit):
ERROR (with brewing unit):
If the absorbed current exceeds 300 mA the display turns red, check the
If the absorbed current exceeds 300 mA the display turns red, check the
brewing unit, the gears on the gear motor and the motor housing in its
brewing unit, the gears on the gear motor and the motor housing in its
seat.
seat.
When the unit reaches the HOME position the indicator changes from “N”
When the unit reaches the HOME position the indicator changes from “N”
to “Y”, the absorbed current, without the brewing unit, must be less than
to “Y”, the absorbed current, without the brewing unit, must be less than
200, and with the brewing unit less than 300 mA
200, and with the brewing unit less than 300 mA
ERROR condition:
ERROR condition:
The HOME indicator always stays on “N”
The HOME indicator always stays on “N”
ERROR:
ERROR:
The HOME indicator changes, and remains permanently on “N”, while the
The HOME indicator changes, and remains permanently on “N”, while the
display changes from green to red; check the microswitch, unit motor (this
display changes from green to red; check the microswitch, unit motor (this
may be blocked) and the wiring JP16.
may be blocked) and the wiring JP16.
ERROR (without brewing unit):
ERROR (without brewing unit):
If the absorbed current exceeds 200 mA the display turns red, check the
If the absorbed current exceeds 200 mA the display turns red, check the
gears on the gear motor and the motor housing in its seat.
gears on the gear motor and the motor housing in its seat.
Press the coffee button to move the brewing unit to the “HOME” position
ERROR (with brewing unit):
ERROR (with brewing unit):
If the absorbed current exceeds 300 mA the display turns red, check the
If the absorbed current exceeds 300 mA the display turns red, check the
brewing unit, the gears on the gear motor and the motor housing in its
brewing unit, the gears on the gear motor and the motor housing in its
seat.
seat.
Press STAND_BY “
Press STAND_BY “
” to move to the next screen
” to move to the next screen
13
Summary of Contents for Intelia
Page 3: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 1 INTRODUCTION...
Page 9: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 3 USER INSTRUCTIONS...
Page 24: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 4 OPERATING LOGIC...
Page 33: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 5 TROUBLESHOOTING...
Page 56: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 6 STANDARD CHECKS...
Page 59: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 7 DISASSEMBLY...
Page 71: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 8 NOTES...
Page 72: ...INTELIA 08 NOTES Saeco International Group Rev 02 September 2012 Page 01 01...
Page 73: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 76: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM...