English
35
3
Coffee unit
-
Remove the coffee dispensing pipe (ref.
T
, fig. 25) .
-
Rotate the lever (ref.
A
, fig. 25) to position 3.
-
Pull the unit maintaining the lever to position 3.
-
Rinse the unit in warm water, with particular attention to clean
the upper filter (ref.
F
, fig. 26)
-
Dry the unit and replace it maintaining the lever in position 3.
Important
While inserting the unit make sure that reference arrows are
aligned. Otherwise align them (fig. 26) using the provided
key.
Mixer and dispenser
-
Remove the instant product funnel (ref.
A
, fig. 27) along with
the funnel cover (ref.
B
, fig. 27).
Separate them from the lower part sliding also the silicon pipes
from the nozzles (ref.
C
, fig. 27).
-
Rotate the coupling nut (ref.
D
, fig. 27).
-
Pull out the mixer unit (ref.
E
, fig. 27).
-
Clean the mixer fan (ref.
F
, fig. 27) with a sponge damped in
warm water without pressing too much not to compromise the
positioning of the gasket.
-
Rinse abundantly in warm water all components and reassem-
ble them following the reverse order of operations.
Pay particular attention to the proper insertion of silicon pipes
into the mixer nozzles (ref.
C
, fig. 27).
fig. 25
99588.38
A
fig. 26
99588.24
F
fig. 27
99588.19
B
Spiral mixer and dispenser
-
Remove instant product funnel (ref.
A
, fig. 28) along with the
funnel cover (ref.
B
, fig. 28). Separate them from the lower
part sliding also the nozzle through the silicon pipe (ref.
C
, fig.
28).
-
Press coupling cursor (ref.
D
, fig. 28).
-
Pull out the mixer unit.
-
Rinse abundantly with warm water all components and reas-
semble them by reversing the order of the above operations.
Pay particular attention to the proper insertion of the silicon
pipe into the mixer nozzle (ref.
C
, fig. 28).
fig. 28
99588.21
B
T
A
E
C
D
F
C
A
C
D
Summary of Contents for D.A. 8P Instant