English
10
6.1
List of accessories
·
Key to enable microswitch (ref.
A
, fig. 5) for deactivation of
security system
·
Stirrerer set for accepted prices and coins
·
Set of labels instructions and original products
·
N. 1 coin conveyor
·
N. 1 coffee unit activation key
·
N. 1 Operation and Maintenance booklet
·
N. 1 power supply cable
6.2
Unit positioning
-
Position the vending machine at a certain distance from walls
or partitions, as shown in figure (fig.10).
Important
To guarantee a proper ventilation, vending machine rear panel
must be kept at a certain distance from walls, partitions, etc.,
of at least 15 cm.
Do not cover the vending machine with clothes or other.
6.3
Water connection
-
Connect the vending machine to a drinking water supply pipe
with a pressure ranging between 1.5 ad 8 bars.
For this purpose utilise a filling pipe of adequate characteris-
tics and connect it to a G3/4 hose” located on the vending
machine rear panel (fig.12).
Important
We recommend that the vending machine be supplied with
water treated by a descaling device, particularly for water
with high content of calcium and magnesium (hard water).
-
Position the vending machine on a surface of adequate dimen-
sions, horizontal and able to support its weight.
-
The palette cannot be tilted more than 2
°
.
If necessary, adjust its feet.
Danger
For additional positions of the vending machine, you have to
empty the Air break tank (ref.
37
, fig.1), acting on the spring
(ref.
A
, fig.11) that closes the drain tube.
15 cm
99588.15
fig. 10
99588.36
fig. 11
A
6.4
Electric connection
Danger
Operation to be performed by the Maintenance technician.
-
Plug the cable into the socket (ref.
34
, fig.1) located in the rear
panel.
The vending machine is preset for the electric operation with a
monophase voltage whose value is evidenced in the identifi-
cation label (see “2.4 Vending machine identification”).
Danger
Electric socket connection has to be located in a place easily
reachable by the supply operator, so that he can easily un-
plug the vending machine from the electric line, whenever
necessary.
Before the connection make sure that:
• The socket main voltage to which the vending machine is con-
nected must be in compliance with the one indicated on the
label.
• The electric system to which the vending machine is connected
complies with current regulations and have the characteristics
to support the maximum load indicated by the label.
If you have doubts, request an accurate control of the system
by qualified personnel.
Danger
It is forbidden to use any extension cord or adapter.
fig. 12
99588.1
Summary of Contents for D.A. 8P Instant