11

E X T E R N A L   M A G N E T I C   A N T E N N A   M O U N T I N G

The WPC-2 is equipped with an external antenna that can be mounted up to 3 meters from the 

 

WPC-2 unit.  The antenna is required as the WPC-2 enclosure is metallic and will block the RF signal 

 

from the remote control. 
The antenna has a magnetic base and may simply be placed on top of the WPC-2 enclosure.  
If moving the antenna elsewhere within 3 meters is desired due to the location of the WPC-2, use the 

included 90 degree, wall mounting bracket to raise or move the antenna into a clear receiving zone.  

 

While not required, best range performance is found when the remote and the antenna are within line 

 

of sight and 100’ or less.  

NOTE:

  The remote function of this device operates through radio frequency (RF) signals.  

 

As with any RF device, this is subject to interference through surroundings and installation location.  

 

In the event of an interference issue or if longer range is required, the 3 meter magnetically mounted 

antenna may be removed and a 15 meter accessory antenna kit may be used to extend the RF antenna 

towards the use area - part number 

pLX-ANTKT-L

.  Like any radio device, experimentation may be 

 

required to locate the best reception or RF friendly spot.

 

6

NOTES:  UNLESS OTHERWISE SPECIFIED.

POWDER COAT WITH LIGHT TEXTURE AT .18 .06.

1.

GRAPHICS TO BE BLACK, LOCATED AS SHOWN ON COVER SIZED APPROXIMATELY 1.75" X 8.0".

2.

GRAPHICS ARTWORK ON PAGE 3.

3.

PRETREAT MATERIAL BEFORE POWDER COATING:

4.

CLEAN, ACID BATH, DEGREASE, ZINC PLATE TO A MINIMUM THICKNESS OF 0.015MM, DEGREASE,

DRY, POWDER COAT.

POWDER COAT MUST BE FROM NAN PAO RESIN CHEMICAL COMPANY, LTD. PART NUMBER T76A4-WH003.

5.

USE TUBULAR, SOLID, RIVETS TO INSTALL HOOK TO COVER.

HINGE PIN TO BE FREE OF PAINT.

8.  PAINT MUST BE RATED FOR A MINIMUM OF 300HRS SALT SPRAY TEST AND ACID RESISTANCE.

7

362.25

420

A

A

B

B

C

C

12.70

13.30

199.35

6.68

SECTION A-A

HOOK

6

200

106.59

SECTION B-B

7

7

HINGE

6

6

14.88

SECTION C-C

REFER TO PAGE 3 FOR

CORRECT DASH NUMBER

AND ARTWORK TO BE USED

±

DOOR,WPC-2/3

USED ON

APPLICATION

NEXT ASSY

APPROVALS

18GA CRS

DO NOT SCALE DRAWING

MATERIAL:

FINISH:

SEE NOTES

PURCHASING MGR:

V.P. MFG:

DIR. ENGR:

SAFETY SPECIALIST:

Q.C. MGR:

UNLESS OTHERWISE SPECIFIED 

DIMENSIONS ARE IN MILLIMETERS.

TOLERANCES ARE:

MODIFIED BY:

FRACTIONS

±

DECIMALS

PROJECT ENGR:

DRAWN BY:

ANGLES

±

UL FILE NO.:

B

SCALE=

SIZE

DWG NO.:

DATES

REV.

SHEET 1 OF 3

THIRD ANGLE PROJECTION

REV

A

RELEASE TO PRODUCTION.

DESCRIPTION

ZONE

ECO NO.

F0477

_

DATE

5/18/06

APPROVED

RB

REVISIONS

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION 

WHICH SHALL NOT BE REPRODUCED, TRANSFERRED TO 

OTHER DOCUMENTS, DISCLOSED TO OTHERS, USED FOR 

MANUFACTURING OR ANY OTHER PURPOSE WITHOUT 

PRIOR AUTHORIZATION OF S.R. SMITH.

A. KIM

07/28/05

94-15089-00

C

1:4

 

 

.25

1

-

K.MARTIN

06/26/14

2/7/07

SC

2/21/07

RB

2/21/07

HLS

2/21/07

HLS

2/21/07

DJ

_

_

ADD -01 FOR WPC3

F0501

B

2/21/07

RB

C

485

UPDATE LOGO AND COMPANY NAME

6/28/14

BS

3 METER LONG ANTENNA CORD

Summary of Contents for WPC2 T Series

Page 1: ...AC 60Hz applications Installation Instructions Read these instructions in their entirety before performing any installation work FOR USE WITH POOL AND SPA PRODUCTS 4008814 ETL LISTED Conforms to UL ST...

Page 2: ...2...

Page 3: ...RING INSTRUCTIONS 7 Power Connections 7 Hooking up Low Voltage Lights to Circuit 1 8 Hooking up Low Voltage Lights to Circuit 2 9 Wiring Diagram 10 EXTERNAL MAGNETIC ANTENNA MOUNTING 11 PUMP CONNECTIO...

Page 4: ...Relay 3 1 94 15264 00 WPC Receiver 2 circuit 4 1 94 15263 00 Remote Control 2 circuit Transmitter 5 1 PLX ANTKT S 3 meter magnetic mount antenna Kit 6 1 44 15037 00 Transformer 12V OPTIONAL ACCESSORY...

Page 5: ...s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Page 6: ...rque Max Motor Load Continuous Duty General Purpose Branch Circuit Breaker Rating General Purpose Branch Circuit Maximum Current Capacity Line and Neutral Main Lugs Neutral and Ground 120V 240V AWG AM...

Page 7: ...To make power connections remove 3 8 inches of insulation from wire ends Connect bare wires to the Load Center as illustrated T ighten terminal screws firmly 20 lb in minimum Connect the common to the...

Page 8: ...tion to store service loop cable Use appropriate wire from the separate 12VAC output block terminals L1 L2 to supply Low Voltage power from the WPC2 XXXX T to the approved Pull Junction or Bell Box Us...

Page 9: ...WPC 2 As illustrated connect lights that will be operated by the Circuit 2 Switch to the Circuit 2 terminal Connect the Neutral to the Terminal Block marked Neutral Connect the Ground to the Equip GND...

Page 10: ...AL NEUTRAL CIRCUIT 2 12 VAC 12 VAC TC POWER TC NEUTRAL BK CIRCUIT 1 FOR USE ON WPC AUXILIARY RELAY KIT FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION BK R BR BK 6 7 5 3 BK BR W R 1 2 8 4 6 9 5 8 4 7 3 2...

Page 11: ...less NOTE The remote function of this device operates through radio frequency RF signals As with any RF device this is subject to interference through surroundings and installation location In the ev...

Page 12: ...nnect a 240V 30AMP Circuit Breaker for each pump if this control box is equipped with optional pump relays Using an appropriately sized copper wires connect to the outer contacts of the JQX relays of...

Page 13: ...he Timer function switch is set to Auto for timer control of the Pump as illustrated below To turn off timers automatic functions set the Timer function switch to OFF To manually turn on the Pump set...

Page 14: ...OFF position NOTE If a toggle switch is in the OFF position wireless remote operation of the device will be disabled To re enable wireless remote operation flip the toggle switch back to the REMOTE po...

Page 15: ...HANGE to toggle on and off the power of Zone 2 on the WPC panel Color Changing Operation To change LED pool light colors simply toggle the power OFF then ON using the button marked 1 or 2 within 1 sec...

Page 16: ...C P O Box 400 Canby OR 97013 P 503 266 2231 TF 800 824 4387 srsmith com 2019 S R Smith All rights reserved 79 15224 00 REV C Questions Contact One of Our Dedicated Lighting Specialists 1 800 824 4387...

Reviews: