13
O P E R AT I N G I N S T R U C T I O N S
T i m e r O p e r a t i o n
Set time to current time. In the example below, the current time is set for 9:00pm.
NOTE:
Only turn the Timer dial clockwise or the timer will be damaged.
Once the time has been set to the current time, set the hours of the Pump operation by “snapping”
the timer tabs inwards towards the center.
NOTE:
Each tab represents 15 minutes of operation and tabs set inwards towards the center is for
OFF operations and ON when the tabs are set outwards as illustrated.
In the example below, the Pump will be off from 12:00pm to 11:45pm.
Once the time and time of operation has been set, ensure that the Timer function switch is set to Auto
for timer control of the Pump as illustrated below.
To turn off timers automatic functions, set the Timer function switch to OFF.
To manually turn on the Pump, set the Timer function switch to the ON position.
NOTE:
When in the ON position, the Pump will continue to run until the Timer function switch
is set to Auto where the tabs at the Set Point is in the OFF position or if the Timer function
switch is rotated to the OFF position.
Apply the timer label to the timer cover plate. Close the timer cover firmly after timer is set.
TIMER DIAL ROTATION
DIRECTION INDICATOR
TIMER TABS SET TO
ON POSITION
TIMER PLATE
TIMER TABS SET TO
OFF POSITION
CURRENT TIME AND TIMER
FUNCTION SWITCH SET POINT
AM HOURS
PM HOURS
TIMER FUNCTION SWITCH
TIMER DIAL
TIMER FUNCTION SWITCH POSITION
| : ON
UP
O
: AUTO MIDDLE
O
: OFF
DOWN
TIMER COVER