13
Caution! In the event of any connection the safety
wire must be connected to the
Recommen-
ded
type
of connection
lead
PE terminal
1
For 230 V earthed one–phase
connection, bridges connect 1–2–3
terminals and 4–5 terminals, safety
wire to
.
2
For 400/230V earthed three–phase
connection, bridges connect 4–5 ter-
minals, phases in succession 1,2 and
3, earth to 4–5, the safety wire to
.
INSTALLATION
Electrical connection
Warning!
All electrical work should be carried out by a qualified and authorised electrician.
Fitting guidelines
The oven is manufactured to work with three–phase alternating current (400V 3N~50Hz).
The voltage rating of the oven heating elements is 230V. Adapting the oven to operate
with one-phase current is possible by appropriate bridging in the connection box according
to the connection diagram below. The connection diagram is also found on the cover of the
connection box. Remember that the connection wire should match the connection type and
the power rating of the oven.
The connection cable must be secured in a strain–relief clamp.
Warning!
Remember to connect the safety circuit to the connection box terminal marked with . The
electricity supply for the cooker must have a safety switch which enables the power to be cut
off in case of emergency. The distance between the working contacts of the safety switch
must be at least 3 mm.
Before connecting the oven to the power supply it is important to read the information on
the
and the connection diagram.
rating label
H05VV-F3G4
CONNECTION DIAGRAM
Caution! Voltage of heating elements 230V
H05VV-F5G1,5