defective, deformed, wet or showing signs of overheating. Do
not reapply power until repairs have been completed.
Before using the fixture, check that all power distribution
equipment and cables are in perfect condition and rated for the
current requirements of all connected devices.
Use only Neutrik PowerCon cable connectors to connect to the
fixture’s power sockets.
Do not connect devices to power in a chain that will exceed the
electrical ratings of any cable or connector used in the chain.
The supplied power input cable is rated 6 A and can safely
supply only one fixture with mains power. Do not connect any
device to the fixture’s MAINS OUT connector when using this
cable. If you replace this cable and also use the replacement
cable to supply only one fixture with mains power, the
replacement cable must also be rated 6 A minimum, have three
conductors 18 AWG or 0.75 mm² minimum conductor size, have
an outer cable diameter of 6 - 15 mm (0.2 - 0.6 in.) and be
temperature-rated to suit the application. In the USA and
Canada the cable must be UL listed, type SJT or equivalent. In
the EU the cable must be type H05VV-F or equivalent.
To connect fixtures to mains power in a chain, you must first
obtain 14 AWG or 1.5 mm
2
power input and throughput cables
that are 16 A rated and temperature-rated to suit the
application. In the USA and Canada the cables must be UL-
listed, type SJT or equivalent. In the EU the cables must be type
H05VV-F or equivalent. Suitable cables with Neutrik PowerCon
connectors are available from Martin™ (see ‘Accessories’ on
page 47). If you use these cables, you can connect fixtures to
power in a linked chain, MAINS OUT throughput socket to
MAINS IN input socket, but do not link more than:
•
five (5) RUSH MH 4 fixtures in total at 100-120 V, or
•
ten (10) RUSH MH 4 fixtures in total at 200-240 V.
The voltage and frequency at the MAINS OUT socket are the
same as the voltage and frequency applied to the MAINS IN
socket. Only connect devices to the MAINS OUT socket that
accept this voltage and frequency.