22
RUSH MH 4 Beam User Manual
2. Use the DOWN and UP buttons to select AUTO TEST and press ENTER
to confirm. The fixture will run an automatic test sequence of all the
effects.
Manual test (manual control of individual effects)
To test individual effects:
1. Select
FIXTURE
TEST
and press ENTER to confirm.
2. Use the DOWN and UP buttons to select MANUAL TEST and press
ENTER to confirm.
3. Select the function you want to test and press ENTER to confirm. You can
now test that function.
4. To return to the previous menu level, press MENU.
Fixture information
Fixture operating hours counter (non-resettable)
To see how many hours the fixture has been used since manufacture:
1. Select FIXTURE INFORMATION and press ENTER to confirm.
2. Use the DOWN and UP buttons to select FIXTURE USE TIME and press
ENTER to confirm. The number of hours will be shown.
Lamp operating hours counter (resettable)
This counter can be reset. It can be used to monitor the number of lamp
operating hours and help you decide when a lamp change is required.
1. Select FIXTURE INFORMATION and press ENTER to confirm.
2. Use the DOWN and UP buttons to select LAMP ON TIME and press
ENTER to confirm. The fixture will display the number of hours the lamp
has been on since the counter was last reset.
3. Use the DOWN and UP buttons to select EXIT to leave the lamp hours
menu or RESET TIME to reset the lamp hours counter to zero. Press
ENTER to confirm.
Firmware version
To see which software version is installed in the fixture:
1. Select FIXTURE INFORMATION and press ENTER to confirm.
2. Use the DOWN and UP buttons to select FIRMWARE VERSION and
press ENTER to confirm. The firmware version will be shown.