42
RUSH MH 4 Beam User Manual
Error messages
Error:
Appears when:
Lamp Startup Fail
No lamp detected or wiring fault.
Temperature Sense Error
Temperature sensor on the PCB is damaged.
Contact your RUSH by Martin authorized distributor
for assistance.
Lamp Too Hot Low Power Temperature higher than 105º C detected. The
fixture runs at a low power level.
Lamp Too Hot Power Off
Temperature higher than 110° C detected. Check
that ambient temperature does not exceed 40° C.
Check that fixture is adequately ventilated. The
fans or temperature sensor might be damaged.
Contact your RUSH by Martin authorized distributor
for assistance.
Maintenance Fixture
Service countdown timer has reached zero. Service
the fixture, then reset the countdown countdown
timer in the control menu.
Lamp On Over 2000 Hour The lamp has had more than 2000 hours of use.
Change the lamp as directed in this manual.
Continuing to use the lamp increases the risk of a
lamp explosion.
Memory Initial Fail
Damaged memory IC. Contact your RUSH by
Martin authorized distributor for assistance.
CPU-B Error
CPU-C Error
CPU-D Error
CPU, PCB or fixture wiring is damaged. Contact
your RUSH by Martin authorized distributor for
assistance.
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Gobo Reset Fail
Focus Reset Fail
These can appear when powering on or resetting
the fixture and can indicate damage to sensors or
components. Contact your RUSH by Martin
authorized distributor for assistance.