 CAUTION

• 

All wiring should be done by a licensed electrician in accordance with state codes, local codes, and National Electrical Code (NEC) or International Electric 
Commission (IEC) standards. 

• 

Improper installation may result in serious injury and void warranty. 

• 

Contains parts and assemblies susceptible to damage by electrostatic discharge (ESD).

• 

Surge protective devices should be utilized for fixtures installed in environments subject to power surges outside the specified operating parameters.

Tools and Materials

(1) #3 Phillips head screw driver
(1) 3/4 inch wrench
(1) 9/16 inch wrench
(1) 1/2 inch wrench 
(1) channel lock pliers 

Mounting

There are several options available for mounting the Meridian Series. Installation instructions for the two primary options are provided below. Follow the one that 
corresponds to your application.

Figure 2

Figure 1

 6.4

3 mm

Pipe Mount

1. 

Verify the voltage listed on the product label is the same as the voltage to be supplied to the fixture.

2. 

Verify outer pipe diameter matches pipe mount adapter (Figure 1). 

3. 

Attach pipe mount adapter to the trunnion bracket using two 3/8 inch cap screws, two split lock washers and two flat washers. Torque screws to 24-27 N-m.

4. 

Install cord grip to pipe mount using the cord grip nut provided (Figure 2).

5. 

Thread power supply cord through cord grip on pipe mount adapter. Pull cord through so 300-380 mm remain on the fixture side of the adapter (Figure 2). 
Tighten cord grip, hand tight plus ¼ turn.

6. 

Lift fixture and slide pipe mount adapter onto pipe.

7. 

Install four 5/16 cap screws into adapter. Rotate fixture to desired orientation and tighten screws to 13-16 N-m.

250 Model Weight

500 Model Weight

14.0 kg (31.0 lb)

18.0 kg (40.0 lb)

Summary of Contents for Meridian Series

Page 1: ...l options available for mounting the Meridian Series Installation instructions for the two primary options are provided below Follow the one that corresponds to your application Figure 2 Figure 1 6 43 mm Pipe Mount 1 Verify the voltage listed on the product label is the same as the voltage to be supplied to the fixture 2 Verify outer pipe diameter matches pipe mount adapter Figure 1 3 Attach pipe ...

Page 2: ... inside junction box tighten cord grip hand tight plus turn 5 Reattach junction box cover Tighten screws to 0 8 N m incoming power line ground neutral N G L fixture cord black ground white Figure 4 Trunnion Mount 1 Verify the voltage listed on the product label is the same as the voltage to be supplied to the fixture 2 Attach fixture to a structure suitable to the weight and size of the fixture us...

Page 3: ...rovided with a pole mount adapter the fixture can also be rotated horizontally as needed Loosen the two bolts holding the fixture to the adapter rotate to the desired orientation and retighten screws Figure 6 0 5 5 15 15 10 20 10 20 Figure 5 Figure 6 58 Safety Cable Installation Safety cable use is strongly suggested when installing the Meridian Series fixtures 1 Locate a sturdy support structure ...

Page 4: ...50 Model 500 power draw 260W 520W current at 480V 0 5A 1 1A current at 347V 0 7A 1 4A current at 277V 0 9A 1 8A current at 120V 2 1A 4 2A inrush current 2 8 A2 s 3 87 A2 s Maintenance The Meridian Series fixtures feature a self cleaning enclosure However additional cleaning may occasionally be required to maintain optimal performance Clean the light engine lenses with a soft cloth and clean water ...

Reviews: