Amp Draw

Model 250

Model 500

power draw

260W

520W

current at 480V

0.5A

1.1A

current at 347V

0.7A

1.4A

current at 277V

0.9A

1.8A

current at 120V

2.1A

4.2A

inrush current

2.8 A

2

s

3.87 A

2

s

Maintenance

The Meridian Series fixtures feature a self-cleaning enclosure. However, additional cleaning may occasionally be required to maintain optimal performance. Clean 
the light engine lenses with a soft cloth and clean water. Do not use abrasives or strong detergents as they may cause irreparable damage and reduce performance.  

Summary of Contents for Meridian Series

Page 1: ...l options available for mounting the Meridian Series Installation instructions for the two primary options are provided below Follow the one that corresponds to your application Figure 2 Figure 1 6 43 mm Pipe Mount 1 Verify the voltage listed on the product label is the same as the voltage to be supplied to the fixture 2 Verify outer pipe diameter matches pipe mount adapter Figure 1 3 Attach pipe ...

Page 2: ... inside junction box tighten cord grip hand tight plus turn 5 Reattach junction box cover Tighten screws to 0 8 N m incoming power line ground neutral N G L fixture cord black ground white Figure 4 Trunnion Mount 1 Verify the voltage listed on the product label is the same as the voltage to be supplied to the fixture 2 Attach fixture to a structure suitable to the weight and size of the fixture us...

Page 3: ...rovided with a pole mount adapter the fixture can also be rotated horizontally as needed Loosen the two bolts holding the fixture to the adapter rotate to the desired orientation and retighten screws Figure 6 0 5 5 15 15 10 20 10 20 Figure 5 Figure 6 58 Safety Cable Installation Safety cable use is strongly suggested when installing the Meridian Series fixtures 1 Locate a sturdy support structure ...

Page 4: ...50 Model 500 power draw 260W 520W current at 480V 0 5A 1 1A current at 347V 0 7A 1 4A current at 277V 0 9A 1 8A current at 120V 2 1A 4 2A inrush current 2 8 A2 s 3 87 A2 s Maintenance The Meridian Series fixtures feature a self cleaning enclosure However additional cleaning may occasionally be required to maintain optimal performance Clean the light engine lenses with a soft cloth and clean water ...

Reviews: