Operation
Runco X-200i Series Installation/Operation Manual
65
PRE
L
IMINAR
Y
•
REC709
chooses the REC709 color gamut.
• Select
S
MPTE-C
to choose the SMPTE-C color gamut.
• Select
EBU
to choose the EBU color gamut.
• Select
Native
to use REC709 for cyan, magenta, and yellow and uncorrected values
for red, green, and blue.
• Select
PCE
to use the Personal Color Equalizer feature of the X-200i. PCE lets you
define a custom color gamut. Refer to
PCE
on page 67 for instructions on how to do
this.
Table 4-2 lists the x- and y-coordinates for each primary and secondary color component.
S
atCo:
Select SatCo from the Advanced Image menu to enable (
On
) or disable (
Off
)
BrilliantColor processing, which improves brightness in grays and secondary colors by
using the spoke light from the color wheel.
Adaptive Contrast:
Adaptive Contrast enhancement expands the light and dark portions
of an output image according to the mean luminance of the input image.
Table 4-2. x/y Color Gamut Values
Primary
Color
Color Gamut
S
ettings and Associated x/y Values
REC709
S
MPTE “C”
EBU
x
y
x
y
x
y
Red
0.640
0.330
0.630
0.340
0.640
0.330
Yellow
0.419
0.505
0.421
0.507
0.418
0.502
Green
0.300
0.600
0.310
0.595
0.290
0.600
Cyan
0.225
0.329
0.231
0.326
0.220
0.329
Blue
0.150
0.060
0.155
0.070
0.150
0.060
Magenta
0.321
0.154
0.314
0.161
0.328
0.158