Serial Communications
82
Runco LS-3/LS-5 Installation/Operation Manual
PRE
L
IMINAR
Y
RS-232 Error Codes
If an
errcode ?
command returns one of the following values, you have encountered a
likely system error requiring the attention of a qualified service technician. Try resetting the
projector by powering it off, allowing it to cool and powering it on again. Refer to Table 6-3
and contact your dealer if the problem persists.
The specific code number identifies the source of the error detected, and is particularly
useful in cases where the projector is far away. For example, the code “7” means that
Fan 1 has failed.
➤
Table 6-3. RS-232 Error Codes
Error Code
LED Indication
Description
0
Inlet NTC thermal sensor is over temperature.
1
DMD NTC thermal sensor is over temperature.
2
Lamp 1 over temperature.
4
Ballast 1 over temperature.
6
Fan failure upon system power-up.
7
Fan 1 failed.
8
Fan 2 failed.
9
Fan 3 failed.
10
Fan 4 failed.
11
Fan 5 failed.
12
Fan 6 failed.
15
DDP3021 communication failure upon system
power-up.
16
Lamp failed to ignite (three attempts) upon system
power-up.
17
Lamp failed during operation.
18
Ballast UART communication failure.
19
PCF8575 external GPIO communication failure.
20
Lamp door is open.
21
Gennum SPI communication failure upon system
power-up.
22
System hardware I2C communication failure.
23
System software I2C communication failure.
24
EEPROM checksum error.
25
EDID checksum error.
Summary of Contents for LightStyle LS-3
Page 2: ......
Page 10: ...x Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Page 16: ...List of Figures xvi Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Page 105: ......
Page 106: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1033 00 Rev A November 2009...