Serial Communications
Runco LS-3/LS-5 Installation/Operation Manual
81
PRE
L
IMINAR
Y
status
?
0 = Standby
1 = Powering Up
2 = Displaying
3 = Cooling Down
4 = Error
errcode
?
Refer to
RS-232 Error
Codes
, below.
msgbox
= ?
0 = On
1 = Off
This control enables or
disables the display of
power off, source and
adjustment message
boxes (brightness, con-
trast etc.). Default value is
ON.
cal.text1
cal.text2
cal.text3
=
Up to 30 characters.
The LS-3/LS-5 start-up
screen is customizable
with three lines of text of
up to 30 characters each.
This text appears below
the “CALIBRATED FOR:”
text in the logo screen.
The allowable characters
are all numbers, letters
(uppercase and lower-
case), spaces, and sym-
bols available in the ASCII
code set.
Table 6-2. Serial Commands (continued)
Operation
Commands
Values
Notes