Running the Setup Wizard and Logging On to the Web Interface
Step 2: Configure the Management IP Address Settings
SmartCell Gateway 200 Getting Started Guide for SmartZone 3.4, 800-71126-001 Rev A
44
The following network settings are required (others are optional):
-
IP address
-
Netmask
-
Default gateway
b
If you clicked
IPv4 and IPv6
at the beginning of this procedure, under the
IPv6
section, click
Auto Configuration
if you want the management (web)
interface to obtain its IP address from Router Advertisements (RAs) or from
a DHCPv6 server on the network. If you want to manually assign the IPv6
network address, click
Static
, and then set the values for the following:
-
IP address
(IPv6): Enter an IPv6 address (global only) with a prefix length
(for example,
1234::5678:0:C12/123
). Link-local addresses are
unsupported.
-
Gateway
: Enter an IPv6 address (global or link-local) without a prefix
length. Here are examples:
•
Global address without a prefix length:
1234::5678:0:C12
•
Link-local address without a prefix length:
fe80::5678:0:C12
5
At the bottom of the screen (see
), select the interface that you want
to set as the default system gateways for IPv4 and IPv6 (if enabled), and then
type the primary and secondary DNS server addresses.
NOTE:
The appropriate interface to use as the default system gateway depends
on the topology of your network. See
Important Notes About Selecting the System
for more information.