![Ruckus Wireless ICX 7150-24 Hardware Installation Manual Download Page 80](http://html1.mh-extra.com/html/ruckus-wireless/icx-7150-24/icx-7150-24_hardware-installation-manual_1498875080.webp)
Perform the following steps to change the host name and then the chassis name.
1. Customize the host name, contact, and location using the following commands. When you configure a host name, the name
replaces the default system name in the device CLI prompt.
device(config)# hostname sj_device1
sj_device1(config)# snmp-server contact Support Services
sj_device1(config)# snmp-server location San Jose
sj_device1(config)# end
sj_device1# write memory
The name, contact, and location each can be up to 255 alphanumeric characters. The text strings can contain blanks. The SNMP
text strings do not require quotation marks when they contain blanks but the host name does.
2. Change the chassis name by using the
chassis name
command.
device(config)# chassis name SJ001
sj_device1(config)# end
sj_device1# write memory
The
chassis name
command does not change the device CLI prompt. Instead, the command assigns an administrative ID to the
device.
Setting the date and time
Use the following command to set the current date and time for the device.
device# clock set
hh:mm:ss Current Time
device# clock set 10:05:45
mm-dd-yy/yyyy Current Date
device# clock set 10:05:45 12-01-16
Establishing a connection to the out-of-band
management port
The out-of-band management interface is an RJ-45 Ethernet port that allows you to access, configure, and manage the device from the
network. Perform the following steps to establish a connection to the device using the out-of-band Ethernet management port.
1. Remove the plug from the RJ-45 management port.
2. Connect an Ethernet cable to the device RJ-45 management port and to the workstation or to an Ethernet network containing the
workstation.
NOTE
At this point, the device can be accessed remotely using the CLI or Brocade Network Advisor. Ensure that the device is
not being modified from any other connections. The Ethernet management port also supports auto-MDI and auto-MDIX.
Initial Setup and Verification
Setting the date and time
Ruckus ICX 7150 Switch Hardware Installation Guide
80
Part Number: 53-1004928-05
Summary of Contents for ICX 7150-24
Page 6: ...Ruckus ICX 7150 Switch Hardware Installation Guide 6 Part Number 53 1004928 05 ...
Page 10: ...Ruckus ICX 7150 Switch Hardware Installation Guide 10 Part Number 53 1004928 05 ...
Page 82: ...Ruckus ICX 7150 Switch Hardware Installation Guide 82 Part Number 53 1004928 05 ...
Page 90: ...Ruckus ICX 7150 Switch Hardware Installation Guide 90 Part Number 53 1004928 05 ...
Page 114: ...Ruckus ICX 7150 Switch Hardware Installation Guide 114 Part Number 53 1004928 05 ...