PRODUCT STRUCTURE
TECHNICAL DATA
Model
RSH-M30L
RSH-M50L
RSH-M80L
RSH-M100L
30
50
80
100
3000
3000
3000
3000
Capacity
(L)
Rated
Power(W)
Rated
Voltage(V)
Rated
Pressure(MPa)
Max of Water
Heating
Temperature(°C)
Waterproof
Grade
Dimensions
(mm)
A*B
220-240
220-240
220-240
220-240
0.8
0.8
0.8
0.8
70
±5
70
±5
70
±5
70
±5
IPX4
IPX4
IPX4
IPX4
Ø355*520
Ø355*755
Ø440*785
Ø440*935
Outlet Tube
Isolation Barrier
Pressure Relief Valve
Cold Water Inlet
Thermostat
Aluminum Anode
Temperature
Control Knob
2
Remark: 1 Liter of water=1 kg
a.
Thermal cut-out
will break the circuit to the heating element in any event the
water temperture in the storage tank becomes high(83
℃
±5
℃
).
Should this happen, switch off the heater electrical supply point and contact our
nearest service centre.
b.
Thermal cut-off
helps to prevent the heating element from being damaged in
any event the heater operates without water.
IMPORTANT