Recommended Electrical Connection Recommended Stripping Length
12mm Copper Wire
PVC Cable
MCB / MCCB
10mA ELCB / RCCB
Double Pole Linked
Switch
Table1: Electrical Loading Table
20
Power(W)
Voltage(V)
Conductor
Size(mm )
Rated Current for Circuit
Breaker/Double Pole Linked
Swith(A)
3000
220-240
2.5
(fig.7)
(fig.6)
Green/Yellow
:
E
Incoming Wires
Brown: L
Blue: N
8
ELECTRICAL CONNECTION
This electric storage water heater is completely factory wired to 3-way connector
with L(LIVE), N(NEUTRAL) and E(EARTH) marking.
1. Switch off the electrical power.
2. Remove all 4 cover screws(A,B,C,D) of the heater.
(refer to fig.6)
3. Refer to fig.7 connect electrical wire as follow:
Brown to L(LIVE)
Blue to N(NEUTRAL)
Green/Yellow to E(EARTH)
4. Ensure that the copper wires are properly tightened on the 3-way connector.
5. Replace the front cover.