22 Configuration
OEI-2
Bosch Security Systems, Inc.
Technical Manual
F.01U.287.527
Rev. 01
4.
From the pop-up menu, select
OMNEO Configuration
.
The OMNEO Configuration window appears
.
5.
Verify the
Settings for OMNEO Card
information is correct.
6.
From the Local Channel drop down list, select the
channel
you want to use to communicate from the OMI to the
OEI-2 device.
NOTE:
Non-allocated channels appear with an asterisk next to them.
7.
Select the
Browse icon
to open the Discovered Devices window from which you can choose the device.
The Partner IP Address field automatically populates.
OR
In the Partner Device Name field, enter the name of the
OEI-2
you want to communicate with.
8.
From the Partner Device Type drop down menu, select
OEI-2
.
NOTE:
If the system detects the type of device it is, the Partner Device Type automatically populates.
9.
From the Partner Channel drop down menu, select the
channel
on the OEI-2 to which the OMI communicates.
10.
Click
Apply
.
Summary of Contents for OMNEO OEI-2