KP-32 User Manual
Basic Operation 17
Bosch Security Systems, Inc.
User Manual
F.01U.193.253
Rev. 16
Flashing Red Talk LED & Flashing Display Alternating Pattern of Alpha & (-**-) (Busy)
You cannot talk at this time. This indication occurs when you activate a local IFB key that is already in-use by a keypanel with
a higher IFB priority. It also occurs when you activate any key assigned to a remote destination, but there are currently no
trunks available.
NOTE:
Flashing red is also the intended indication when attempting to talk to a remote IFB while someone else with a
higher trunk IFB priority is already talking. However, this requires ADAM MC version later than 9.9.x and Trunk
MC version later than 7.x.x. Regardless of the indication provided, you are not be heard at the remote location if
your keypanel has the lower trunk IFB priority. IFB trunk priorities are set in AZedit. (Click the KP button on the
AZedit toolbar to access Keypanels / Ports setup, then click the Edit button, then click the Advanced tab. Enter
the desired IFB priority in the fields provided. Be sure to send the change to the intercom system.)
Flashing Green Talk LED & Display Alpha (on time equal to off time)*
There is an incoming call from the destination assigned to the key. Activate the key to talk back.
NOTE:
The duration of incoming call flash is controlled by DIP switch 4 on the KP-32 back panel. See “Option DIP
Switch Settings” on page 8, for further information.
Winking Green Talk LED (on time less than off time)*
Indicates that a key is ready to talk (key is on), but requires external footswitch activation to talk.
Listen LED Indication
The listen LED is the upper LED for each key. The listen LED is green when listen is on.
Intercom Key Operation
Basic Intercom Key Operation
The up position of an intercom key activates listen (if assigned). The down position activates talk (if assigned). If there is no
talk assignment for an intercom key, the talk position of the key does not activate. If there is no listen assignment, the listen
position does not activate.
For momentary activation of a key
press and hold the key
. Then, release it when finished.
For latching operation (if enabled)
tap a key
; it turns on and remain on. Tap the key again to turn it off when finished.
NOTE:
Latching may be turned off for the entire keypanel by setting DIP switch 1 on the KP-32 back panel to the Closed
position. Latching may be disabled for individual keys on a keypanel using AZedit: Click the KP button on the
AZedit toolbar to open the Keypanels / Ports setup screen. Select the intercom port where the keypanel is
connected. Place a check mark in the D check boxes for any keys where you want to disable latching. Be sure to
send your changes to the intercom system.
Summary of Contents for EKP-32
Page 4: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 iv KP 32 User Manual ...
Page 12: ...Bosch Security Systems Inc User Manual 8 KP 32 User Manual Rev 16 F 01U 193 253 ...
Page 14: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 2 KP 32 User Manual ...
Page 88: ...76 Glossary KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Page 114: ...102 KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...