background image

 

 

 

- page 7 of  13 

– 

Inst ruct ion and operat ing manual CVS  
SKL1200 direct  driven                                                                                                                 

(for-030/031013)

    

 

 

Mounting installation 

 

3.1 

Mounting instructions RTI installation powerband driven  

 

While placing the installation on a pallet, make sure the installation is approximately 
30 cm off the ground (raising the installation w ith timber if necessary).   

 

Drive  the  installation  up  to  the  desired  location  next  to  the  truck.  Make  sure  the 
angle of the drive shaft is as small as possible. 

Please find the maximum mounting 

angle in the mounting instructions provided by the truck manufacturer.

 

 

 

 

  

 

 

 

 

 

 

 

 

 

Image 3.1.1 

 

Place  the  installation  at  the  same  level  as  the  chassis  and  parallel  to  the  truck. 
Measure the PTO-

shaft. Make sure the installation doesn’t exceed the w idth of the 

truck.  

 

Measure  the  brackets  and  try  to  use  all 
the  holes  in  the  chassis.  Brackets 
should 

be 

painted 

or 

otherw ise 

protected  against  corrosion.  Use  at 
least  2  brackets  (w ith  a  box  or  tank 
combination  at  least  4  brackets  should 
be used) 

 

Mount  the  brackets  onto  the  chassis 
and onto the installation.  

 

The  installation  is  equipped  w ith  a  24 
Volt  fan:  connect  the  w ires  of  the 
sw itch box (image 3.1.2). 

 

 

Cover the brackets w ith an aluminium 
panel. 

 

 

 

image 3.1.2 

NOTE 

With a vacuum installation the vacuum valve must be set to  -0.5 bar. Please 
note: the vacuum valve should be set w hen testing the installation  before initial 
operation. The vacuum valve has not  been set w hen the installation is delivered 
as a building kit (w ithout mounting by RTI). 

 

 

 

 

 

 

 

Cont rol light  

Connect  t o bat t ery 
 -   =  black 
+   =  red 

Connect  t o fan 
 -   =  black 
+   =  red 

Summary of Contents for SKL1200

Page 1: ...INSTRUCTION AND OPERATING MANUAL Compressor installation SKL1200 direct driven...

Page 2: ...544 377050 The manual provides information about the following installation CVS SKL1200 direct DRIVEN Carefully read these instructions and the compressor instruction before setting up and going into...

Page 3: ...on and training personnel 6 2 3 Operating safety conscious 6 2 4 Safety instructions operator 6 2 5 Modifications and repairing spare parts 6 2 6 Modifications installation 6 3 Mounting installation 7...

Page 4: ...the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 Email info rti nl 1 2 Service...

Page 5: ...31013 1 4 Oil cooler A CVS SKL1200 is equipped with an oil cooler It is very important to keep the oil cooler clean to prevent overheating of the compressor Observe the safety very carefully the enclo...

Page 6: ...nts The latest edition of each of these regulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local con...

Page 7: ...the PTO shaft Make sure the installation doesn t exceed the width of the truck D Measure the brackets and try to use all the holes in the chassis Brackets should be painted or otherwise protected agai...

Page 8: ...ll also start to run and will ensure the supply of oil to lubricate the bearings and the gears The oil pressure shall not fall below 0 3 bar With cold oil it may occur that the required oil pressure i...

Page 9: ...le the air intake filter is soiled and poses a risk of overheating and damages C The safety valve must open at maximum air pressure This valve must NOT be used as blow off valve To prevent overheating...

Page 10: ...e lower edge of the threaded hole 2 ATTENTION When filling via the bore of the vent plug 4 the oil level changes only after a time delay due to the oil flowing in B Check the air intake filter at regu...

Page 11: ...prevent corrosion To carry out the following inspections it is necessary to start the installation without enclosure Please note the dangers that can occur as a result of access to hot parts as compre...

Page 12: ...hange the oil filter Please find the instructions to demount the oil filter in the manual provided with the installation C Demount the non return valve installed in the discharge silencer and check fo...

Page 13: ...Check the insulation material in the enclosure for damages cover back panel floor panel if necessary repair and finish with sealant O Check if the fan louvers are open O Check if the discharge silenc...

Reviews: