background image

 

 

 

- page 10 of  13 

– 

Inst ruct ion and operat ing manual CVS  
SKL1200 direct  driven                                                                                                                 

(for-030/031013)

    

 

5.2 

WEEKLY INSPECTION 

 

 
 

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *  

 

ONLY CARRY OUT WHEN INSTALLATION IS COOL AND AT A STANDSTILL 

 

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

 

 
A: 

Check the level of lubricating oil w eekly. 
 

Unscrew   the  upper  screw   plug  (1)  from  the  oil 
pan  and  check  w hether  the  oil  reaches  the  low er 
edge of the threaded hole (2) (see magnification).  

•   Correct  oil  level  if  necessary.  If  the  oil  level  is 
too  high:  The  oil  flow s  out  of  the  control  bore. 
Collect  oil  and  dispose  of  in  accordance  w ith 
legal regulations.  

•  If the oil level is too low : Top up w ith oil. To do 
this,  either  unscrew   the  higher  of  the  tw o  filling 
screw s  (3)  or  the  vent  plug  (4)  and  slow ly  fill  in 
the  oil  until  the  oil  reaches  the  low er  edge  of  the 
threaded hole (2).  
 

ATTENTION! 

 

When filling via the bore of the vent plug (4), the 
oil  level  changes  only  after  a  time  delay  due  to 
the oil flow ing in.  

 

 
B: 

Check the air intake filter at regular intervals.  

 
Clean or replace the air filter if necessary. 
*   Please  note  that  the  air  filter  is  reinserted  in  the 
same  position  (paying  attention  to  the  front  and 
back of the element). 
 
Also check the functioning of the air indicator. 
 
 
 
 
 

Air filter 

 
 
C: 

It  is  important  to  check  the  airflow   and  cleanliness  of  the  fan  louvres  to  prevent 
overheating of the compressor. 

 

(compressed air cooler and w hen installed the oil cooler) 

 
This  check  may  only  be  carried  out  by  skilled  mechanics.  Observe  the  safety  very 
carefully, the enclosure must be removed and rotating parts will be accessible.  

 
D: 

Check the functioning of the fan. Check if the control light is on (image 3.1.2). You 
w ill find the safety fuse in the sw itch box. 

 
 
 

Summary of Contents for SKL1200

Page 1: ...INSTRUCTION AND OPERATING MANUAL Compressor installation SKL1200 direct driven...

Page 2: ...544 377050 The manual provides information about the following installation CVS SKL1200 direct DRIVEN Carefully read these instructions and the compressor instruction before setting up and going into...

Page 3: ...on and training personnel 6 2 3 Operating safety conscious 6 2 4 Safety instructions operator 6 2 5 Modifications and repairing spare parts 6 2 6 Modifications installation 6 3 Mounting installation 7...

Page 4: ...the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 Email info rti nl 1 2 Service...

Page 5: ...31013 1 4 Oil cooler A CVS SKL1200 is equipped with an oil cooler It is very important to keep the oil cooler clean to prevent overheating of the compressor Observe the safety very carefully the enclo...

Page 6: ...nts The latest edition of each of these regulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local con...

Page 7: ...the PTO shaft Make sure the installation doesn t exceed the width of the truck D Measure the brackets and try to use all the holes in the chassis Brackets should be painted or otherwise protected agai...

Page 8: ...ll also start to run and will ensure the supply of oil to lubricate the bearings and the gears The oil pressure shall not fall below 0 3 bar With cold oil it may occur that the required oil pressure i...

Page 9: ...le the air intake filter is soiled and poses a risk of overheating and damages C The safety valve must open at maximum air pressure This valve must NOT be used as blow off valve To prevent overheating...

Page 10: ...e lower edge of the threaded hole 2 ATTENTION When filling via the bore of the vent plug 4 the oil level changes only after a time delay due to the oil flowing in B Check the air intake filter at regu...

Page 11: ...prevent corrosion To carry out the following inspections it is necessary to start the installation without enclosure Please note the dangers that can occur as a result of access to hot parts as compre...

Page 12: ...hange the oil filter Please find the instructions to demount the oil filter in the manual provided with the installation C Demount the non return valve installed in the discharge silencer and check fo...

Page 13: ...Check the insulation material in the enclosure for damages cover back panel floor panel if necessary repair and finish with sealant O Check if the fan louvers are open O Check if the discharge silenc...

Reviews: