manualshive.com logo in svg
background image

InstructIon manual for:

COMPRESSOR 6LtR 
diRECt dRivE 1.5hP

model no

:  

SA0615

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE REAd thESE iNStRUCtiONS CAREFULLY. NOtE thE SAFE OPERAtiONAL REQUiREMENtS, WARNiNGS & CAUtiONS. 

USE  thE PROdUCt CORRECtLY ANd With CARE FOR thE PURPOSE FOR WhiCh  it  iS  iNtENdEd. FAiLURE  tO  dO SO MAY CAUSE 
dAMAGE ANd/OR PERSONAL iNJURY ANd WiLL  iNvALidAtE  thE WARRANtY. PLEASE KEEP iNStRUCtiONS SAFE FOR FUtURE USE.

1.1.  

ELECtRiCAL SAFEtY

  

WARNiNG! 

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. 
a residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 
device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected 
by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1. the 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable appliance tester (Pat), at least once a year.

1.1.2.  the 

health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.  
 

and use a Portable appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.
1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all  
 

connections to ensure that none are loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

dO NOt

 pull or carry the appliance by the power cable.

1.1.8. 

dO NOt 

pull the plug from the socket by the cable.

1.1.9. 

dO NOt

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an asta/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)   After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer   

  

  insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only.  

 to rewire, connect the wires as indicated above - 

dO NOt

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  
 

that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. a reel with an rcd fitted is preferred since any appliance  
 

plugged into it will be protected. the section of the cores in the cable is important and should be at least 1.5mm², but to be   

 

absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we  

 

recommend the use of 2.5mm² section cable.

1.2. 

GENERAL SAFEtY iNStRUCtiONS

3

 

Familiarise 

yourself with the application and limitations of the compressor. 

 

ensure that the compressor is in good order and condition before use. If in any doubt do not use. contact an electrician or   

 

your service agent.

 

WARNiNG! the compressor must be serviced by an authorised agent only. DO NOT tamper with, or attempt to adjust, the   

 

pressure switch or the safety valve.

Before moving or maintaining the compressor,

 

ensure that it is unplugged from the mains supply and that the air tank pressure has been  

 

vented. 

only use recommended parts and accessories. using unauthorised items may be dangerous and will invalidate your warranty.

read the instructions regarding any air tool/accessory used with the compressor. ensure that the safe working pressure of any air   

 

tool/accessory used exceeds the output pressure of the compressor.

Keep tools and other items away from the compressor when it is in use and keep the area clean and free of unrelated items.

ensure that the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the work area. 

dO NOt

 dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.

dO NOt

 use the compressor outdoors, or in damp or wet locations and 

dO NOt

 operate it within the vicinity of flammable liquids, gases or solids.

dO NOt

 touch compressor cylinder, cylinder head or pipe from head to tank, as these may be hot and will remain so for some time after shutdown.

dO NOt

 attempt to move the compressor by pulling the air supply hose. 

dO NOt

 attempt to lift or move the compressor by any means other than by the handle. 

3

 remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair.

 

Wear approved safety eye protection (standard spectacles are not adequate).

3

 

use the compressor in a well ventilated area, keeping the air vents clear of obstructions.

dO NOt

 restrict air flow around the compressor whilst operating it.

3

 ensure that it is placed on a firm, level surface.

7

 

dO NOt

 operate the compressor if you are tired or under the influence of alcohol, drugs or intoxicating medication. 

1.  SAFEtY iNStRUCtiONS

Original Language Version

sa0615    Issue: 2 - 20/02/12

fuse ratInG: 13amP

Содержание SA0615

Страница 1: ...there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only to rewire connect the wires as indicated above dO NOt connect either wire to the earth terminal 1 1 10 Product...

Страница 2: ...e it should be switched off disconnected from the mains supply and the air drained from the tank Motor output 1 5hp voltage phase 230V 1ph Current 4 8a Air displacement 4 8cfm Max free air delivery 3 4cfm tank capacity 6ltr Max pressure 116psi 8bar Noise level 95dB a Original Language Version sa0615 Issue 2 20 02 12 4 OPERAtiON WARNiNG ENSURE thAt YOU hAvE REAd UNdERStOOd ANd APPLiEd SECtiON 1 SAF...

Страница 3: ... sae 5W50 viscosity alternatively a mineral oil can be substituted when carrying out an oil change after ensuring that the synthetic oil has been thoroughly drained first use a mineral oil of sae 15W40 viscosity WARNiNG do not mix different oils and do not use non detergent low quality oils as the compressor may be damaged dispose of all waste oil responsibly in accordance with local authority req...

Страница 4: ...logged clean or replace filter element 6c compressor does not stop at max pressure Head gasket or valve fault contact authorised service agent 7 compressor noisy with metallic knock Bearing or piston damage contact authorised service agent 8 excessive moisture in discharged air High humidity environment drain tank after each use NOTE It is our policy to continually improve products and as such we ...

Отзывы: