RVV 700 Standard Programming Service and Parts Manual
38
SECTION 3: Vender Programming
•
Lighting Control Disable
If <enter> is pressed at the “Lighting Control Disable”
prompt, the box will toggle between checked or
unchecked. When the desired status is displayed,
pressing <enter> will save that status and return you to
the unhighlighted “Lighting Control Disable” display. If
“Lighting Control Disable” is enabled, all programmed
lighting control timers will be overridden by the key
switch, ensuring illumination at all times.
Checked: lighting control will be disabled when the key
switch is activated (illumination at all times).
Unchecked: lighting control will be enabled when the key
switch is activated (normal function).
•
Refrigeration Disable
If <enter> is pressed at the “Refrigeration X” prompt, the
box will toggle between checked or unchecked. When
the desired status is displayed, pressing <enter> will save
that status and return you to the unhighlighted “the box
will toggle between checked or unchecked. When the
desired status is displayed, pressing <enter> will save that
status and return you to the unhighlighted “Refrigeration
Disable”.
Checked: refrigeration blocking will be disabled when the
key switch is activated (allowing normal refrigeration at
all times).
Unchecked: refrigeration blocking will be enabled when
the key switch is activated.
•
No Vend
If <enter> is pressed at the “No Vend” prompt, the box will
toggle between checked or unchecked. When the desired
status is displayed, pressing <enter> will save that status
and return you to the unhighlighted “No Vend” display.
If “No Vend” is enabled, no selections will be allowed to
vend and a “No Sale” message will be displayed.
Unchecked: no vend will be disabled when the key switch
is activated.
Checked: no vend will be enabled when the key switch is
activated (all selections blocked for sales).
Note: If both “Free Vend” and “No Vend” are enabled,
“No Vend” will be given priority (no vending will be
allowed).
•
Blocking Disable
If <enter> is pressed at the “Blocking Disable” prompt,
the box will toggle between checked or unchecked. When
the desired status is displayed, pressing <enter> will save
that status and return you to the unhighlighted “Blocking
Disable” display. If “Blocking Disable” is enabled, all
programmed time blocks will be overridden by the key
switch, allowing sales at all times.
Checked: selection blocking will be disabled when the
key switch is activated (vending at all times).
Unchecked: selection blocking will be enabled when the
key switch is activated.
Note: “Blocking Disable” is used in conjunction with
“Selection Block X” programming menus.
•
Discounting Disable
If <enter> is pressed at the “Discounting Disable” prompt,
the box will toggle between checked or unchecked.
When the desired status is displayed, pressing <enter>
will save that status and return you to the unhighlighted
“Discounting Disable” display. If “Discounting Disable”
is enabled, all programmed discount sales timers will be
overridden by the key switch, ensuring selections will sell
at full price at all times.
Checked: discounting will be disabled when the key
switch is activated.
Unchecked: discounting will be enabled when the key
switch is activated (normal function).
Summary of Contents for RVV 700
Page 4: ...RVV 700 Standard Programming Service and Parts Manual 4 TABLE OF CONTENTS continued...
Page 42: ...RVV 700 Standard Programming Service and Parts Manual 42 SECTION 5 Troubleshooting...
Page 43: ...43 RVV 700 Standard Programming Service and Parts Manual SECTION 5 Troubleshooting...
Page 74: ...RVV 700 Standard Programming Service and Parts Manual 74 Wiring Schematic...
Page 75: ...75 RVV 700 Standard Programming Service and Parts Manual Wiring Schematic...