RVV 700 Standard Programming Service and Parts Manual
24
SECTION 3: Vender Programming
Close Outer Door (Pass / Fail)
Pressing <enter> at the “Close Outer Door” prompt
will cause the controller to enter the outer door lock test
routine. Upon entry into this routine, the outer door should
lock securely (if it was already open). From “Close Outer
Door”, press <down> to proceed to the next prompt,
“Open Outer Door”.
Open Outer Door (Pass / Fail)
Pressing <enter> at the “Open Outer Door” prompt will
cause the controller to enter the inner door unlock test
routine. Upon entry into this routine, the inner door should
open (if it was closed). From “Open Outer Door”, press
<down> to proceed to the next prompt, “Lock Inner
Door”.
Lock Inner Door (check box)
Pressing <enter> at the “Lock Inner Door” prompt will
cause the controller to enter the inner door lock test
routine. Upon entry into this routine, the inner door should
lock securely. If <enter> is pressed a second time, the
inner door should unlock. From “Lock Inner Door”, press
<down> to proceed to “Light”.
Light (check box)
Upon pressing <enter> at the “Light” prompt, a check
mark should appear in the box on the display and the port
light should illuminate. Pressing <enter> again will cause
the light to shut off. From “Light”, press <exit> to return to
the “Port” prompt. Press <down> to proceed to “Motors”.
Motors
Upon pressing <enter> at “Motors”, the display will show
the current X and Y coordinates of the cup. Press the
following keys to perform the motor tests:
•
Press <up> to test the Y-axis motor by moving
the cup upward. The Y coordinate on the
display should decrease by approximately 50
steps. Pressing <down> should move the cup
downward, with the Y coordinate increasing by
approximately 50 steps.
•
Press <right> to test the X-axis motor by moving
the cup to the right. The X coordinate on the
display should decrease by approximately 50
steps. Pressing <left> should move the cup
leftward, with the X coordinate increasing by
approximately 50 steps.
Pressing <exit> will return the display to the “Motors”
prompt. Press <exit> again to return to “VendMech
Diagnostics”, then press <down> to proceed to “Sensors”.
Sensors
(NOTE: This mode is still in development.)
Calibration
The vend mechanism calibration routines allow the
controller to automatically calibrate vending and delivery
positions. Upon pressing <enter>, “Calibration” will be
highlighted, at which point a password must be entered.
Key in the calibration password (3-4-5-6), followed by
<enter>. After correct entry, the display will show the first
routine, “Package Size Mapping”.
Package Size Mapping
This routine allows the operator to increase or decrease the
number of plunger revolutions required to drive a product
into the delivery cup. If <enter> is pressed, three package
size options can be set: Small, Standard, or Large. The
default package size settings, by number of revolutions,
are:
•
Small: 300 revolutions
•
Standard: 520 revolutions
•
Large: 690 revolutions
Press <up> or <down> to scroll through the available
sizes. To change a setting, press <enter> to highlight the
item, then type in the desired number of revolutions using
the keypad. Press <enter> to save the setting. Once each
package size has been set, press <exit> to return to the
“Package Size Mapping” prompt. Press <up> to proceed to
the next prompt, “Calibrate Selection”.
Calibrate Selection
This routine allows automatic calibration of vending
positions by selection. Upon pressing <enter>, “Calibrate
Selection” will be highlighted, along with “ALL”. Press
<enter> to calibrate all selections, or key in a particular
selection number to calibrate individually. Once
calibration has been performed, press <exit> to return to
the “Calibrate Selection” prompt. Press <up> to proceed to
the next prompt, “Calibrate Port”.
Calibrate Port
This routine allows calibration of the delivery position.
Upon pressing <enter>, the product cup will perform
a delivery routine. Once this routine is complete, the
display will show “Pass”, if the delivery routine has been
performed successfully, or “Fail”, if the product cup
was unable to complete the delivery routine properly. If
calibration of the delivery position fails, an error code
should be recorded.
(See the error display mode, “Errors”,
at the beginning of the Internal Service Menu for more
information.)
Once this routine is complete, press <up> to
proceed to the next prompt, “Lighting Activity Time”.
Summary of Contents for RVV 700
Page 4: ...RVV 700 Standard Programming Service and Parts Manual 4 TABLE OF CONTENTS continued...
Page 42: ...RVV 700 Standard Programming Service and Parts Manual 42 SECTION 5 Troubleshooting...
Page 43: ...43 RVV 700 Standard Programming Service and Parts Manual SECTION 5 Troubleshooting...
Page 74: ...RVV 700 Standard Programming Service and Parts Manual 74 Wiring Schematic...
Page 75: ...75 RVV 700 Standard Programming Service and Parts Manual Wiring Schematic...