6. Fitting the roof part 1

Lift the assembled roof sections onto the building, make sure the top edges are located at the apex and there is an even overhang at each end. From the outside secure
the roof section on the back of the building with 6 x 38mm screws as shown, screw through the roof and roof framing into the top of the wall panels. Attach the front roof
section in the same way using 4 x 38mm screws. From inside the building attach the roof panel framing at the ends of the building to the apex panels using 4 x 50mm screws.
Fix a gusset to the roof rafters using 2 x 30mm nails per gusset.

50mm

38mm

38mm

30mm

30mm

7. Fitting the roof part 2

Align to the internal angled roof edges the two roof join covers, with the bottom edges flush to the roof panel framing, fix in place using 4 x 35mm screws. screw through
the cover into the angled roof panel framing. Assemble the roof centre block with the internal roof capping, have the block sitting central on the cap except at the angled
end where the two components should be flush with each other. Secure the capping to the centre block using 3 x 50mm screws. Screw through the cap into the block as
shown. Lift the two hip roof panels onto the wall and angled roof panels as shown. Ensure they are hooked over the wall panels and butted up against the main roof. From
inside, Fix the panels down to the wall panels using 2 x 50mm screws per panel, screw through the roof panel frame into the top of the wall panels. Using 1 x 38mm screws
per hip roof panel screw through the angled roof panels  into the ends of the top frame of the hip roof panels. Position the roof centre block between the hip roof panels
with the angled end sitting on the main roof, secure in place using 6 x 38mm screws. Screw up through the capping piece into the framing of the hip roof panels. On the
outside of the building secure the hip roof panels to the roof join covers using 3 x 32mm screws evenly spaced along the panel.

35mm

38mm

50mm

50mm

32mm

Important note

From the inside of the building, screw
through the main roof into the top roof frame
of each hip roof panel using 1 x 38mm screw
per roof panel.

Screw into apex panel

Screw into apex panel

Important note

Ensure the bottom edge of
the roof join covers are
flush to the edges of the
main roof panel framing.

Roof centre block and inside capping

Side view

End view

Assemble component

32mm

It is recommended to drill pilot holes with a
3mm drill bit for all screws in this section.

3mm

Drill

It is recommended to drill pilot holes with a
3mm drill bit for all screws in this section.

3mm

Drill

38mm

Summary of Contents for SS225D

Page 1: ... bargeboards 4 39 Left hand bargeboard 1 40 Right hand bargeboard 1 41 Window panel bargeboards 3 42 Front panel bargeboard 1 43 Large window glazing 750x655mm 5 44 Small window glazing 580x255mm 5 45 Large window beading 12x30x728mm 10 46 Large window beading 12x30x657mm 10 47 Small window beading 15x15x555mm 10 48 Small window beading 15x15x257mm 10 49 Roofing felt roll 10m 1 50 Roofing felt rol...

Page 2: ...building is not allowed to sit in pooled water during wet conditions If the building is to sit on soil or grass it MUST be erected on pressure treated wooden 50mm x 50mm or similar bearers These are not supplied in the kit Rowlinson Garden Products recommend using pressure treated bearers with all buildings on any type of base Door end panels Back panels End panels Window panels 50mm 50mm Large ba...

Page 3: ...loor Ensure the panels are sitting square on the floor Secure using 23 x 63mm screws screw through the panel frames and floor into the floor joists 63mm 63mm Floor joists 63mm 5 Roof sections Build the two large roof sections as shown below by joining the panel frames together ensure the frames are flush with each other and secure using 2 x 50mm screws for each panel join 1040mm 1040mm 1132mm 1132...

Page 4: ...o the wall and angled roof panels as shown Ensure they are hooked over the wall panels and butted up against the main roof From inside Fix the panels down to the wall panels using 2 x 50mm screws per panel screw through the roof panel frame into the top of the wall panels Using 1 x 38mm screws per hip roof panel screw through the angled roof panels into the ends of the top frame of the hip roof pa...

Page 5: ... washers It is recommended to drill pilot holes in the weather strips with a 3mm drill bit before assembly Drill 19mm 32mm Ensure the right door has the tower bolt mounting blocks 25mm 8 Fitting the roof part 3 Position the triangular roof panels as shown loosely secure them together using 2 x 50mm screws per join as shown Adjust the roof panels to achieve the best fit Do not fix down to the walls...

Page 6: ...tion At each end and along the lower edge of the roof leave an overhang of felt enough to cover the felt battens Fold down the felt along the lower edge and secure to the felt batten using 28 x10mm felt nails evenly spaced Tension the felt over the roof and secure along the upper edge using 7 x 10mm felt nails Dress down the ends and secure using 3 x 10mm felt nails Use a second of the cut pieces ...

Page 7: ...rill 4 pilot holes evenly spaced along the length of each angled roof coverstrip Apply a good bead of silicon along the underside of the strip Position a strip over each of the roof panel joins as shown tucking each one under the top cap and have the pointed end finishing flush to the edge of the roof Secure each strip with 4 x 25mm screws It is recommended to drill pilot holes with a 3mm drill bi...

Page 8: ... 50mm or similar bearers These are not supplied in the kit Rowlinson Garden Products recommend using pressure treated bearers with all buildings on any type of base Timber Information As timber is a natural material there are certain weather conditions that may affect the materials properties In times of excessive dry spells the material may lose some of its internal moisture causing a certain deg...

Reviews: