background image

Dune MC 

User Manual

Griven S.r.l.

 - Via Bulgaria, 16

46042 Castel Goffredo

Mantova -  Italy

© Copyright Griven 2017 - Griven reserves the right to make 

changes to this product and related instructions at any time 

without prior notice and such changes shall be effective 

immediatly

.

Tel. +39.0376.779483

Fax +39.0376.779682

E-mail: [email protected]

Web: 

www.griven.com

Rev. 1.00

Date: 02/11/2018

Dimensions

Weight / Peso

6,8 Kg (15 Lbs)

Housing / Corpo proiettore

Stainless steel flange / Aluminium body / ABS formwok

IK rating / classe IK

IK10

IP rating / grado IP

IP67

Ambient temp./ Temperatura ambientale

-40°C to 50°C ( -40°F to122°F)

Power supply / Alimentazione

100-240 VAC 50/60Hz

Inrush current / Corrente di spunto

60A @230VAC

Power / Potenza massima 

45 W

Nominal current / Corrente nominale

0,4A@230VAC

Thermal protection / Protezione termica

Electronic

Electrical class / Classe elettrica

I

Cable / Cavo

1 m

Control / Sistema di controllo

USITT DMX-512 RDM

Channels / Canali

4-5-6 (RGBW), 2-3 (Dynamic White), 1 (Monochromatic)

Color range / Colori

6 High output  multichip LEDS additive syntesis

Optics/ Ottiche

spot, narrow, medium, wide

551068

Ø345m

m

13.6”

362mm

14.3”

Ø286m

m

11.3”

78,4mm

3.1”

Ø40m

m

1.6”

Summary of Contents for Dune MC

Page 1: ...m body ABS formwok IK rating classe IK IK10 IP rating grado IP IP67 Ambient temp Temperatura ambientale 40 C to 50 C 40 F to122 F Power supply Alimentazione 100 240 VAC 50 60Hz Inrush current Corrente di spunto 60A 230VAC Power Potenza massima 45 W Nominal current Corrente nominale 0 4A 230VAC Thermal protection Protezione termica Electronic Electrical class Classe elettrica I Cable Cavo 1 m Contr...

Page 2: ...ors unconnected or unprotected for long periods Non lasciare mai per lungo tempo agli agenti atmosferici cavi e connettori non collegati o non protetti Disconnect power before installing or servicing to avoid electrical shock Togliere l alimentazione prima di effettuare qualsiasi operazione all interno dell apparecchiatura Disconnect power before any connection operation Togliere l alimentazione p...

Page 3: ...e instructions provided along with the connection kit Le connessioni dei cavi di alimentazione e segnale possono essere eseguite utilizzando il kit di connessione in dotazione al proiettore Seguite le istruzioni fornite nel kit Mains Power 100 240 VAC 50 60Hz RED ROSSO DATA BLACK NERO DATA WHITE BIANCO COMMON RED ROSSO DATA BLACK NERO DATA WHITE BIANCO COMMON MARRONE BROWN L Live GREEN YELLOW GIAL...

Page 4: ... with your fingers Once achieved the aiming required it is recommended to power up the opened fixture for few minutes in order to let escape the internal moisture then close it This procedure is highly recommended every time the opening of the fixture in needed L angolo di proiezione può essere modificato da 10 a 10 Rimuovere il coperchio e muovere il disco LED premendo con le dita Una volta otten...

Page 5: ...e Line terminator 120Ω not included SLAVE 1 eg CH005 SLAVE n eg CHxxx MASTER eg CH001 DMX mode SLAVE 2 eg CH009 WARNING Use a DMX repeater on each 32nd fixture of the chain or in case the cable lenght exceeds 300m 1000 ft Install a data terminator 120Ω between Data and Data on the DMX out cable of the last unit ATTENZIONE Utilizzare un ripetitore di segnale DMX ogni 32 proiettore della catena o nel...

Page 6: ...LUE BLU 4 WHITE BIANCO DIMMER MODE Monochromatic 0 100 100 0 5 inactivity Automatic LOGOUT 5 inattività Automatic LOGOUT Green Cyan Blue Magenta Red Yellow White Verde Ciano Blu Magenta Rosso Giallo Bianco 4 COLD WHITE BIANCO FREDDO 5 WARM WHITE BIANCO CALDO RGBW RGB DW Setup The fixture must be configured only by using AL1321 IR remote control sold separately and from any DMX RDM compati ble cont...

Page 7: ...nsità Manufacturer viene mostrato in nome del produttore Griven Model description viene mostrato il modello del proiettore Software version description viene mostrata la attuale versione software installata sull apparecchio Temperature viene mostrata l attuale temperature dei LED Mode Modo Channel Canale Function Funzione Value Valore 4 1 0 100 Red 0 255 2 0 100 Green 0 255 3 0 100 Blue 0 255 4 0 ...

Page 8: ...rimane attivo fino al raggiungimento della temperatura di esercizio POWER ON LEDs OFF LEDs ON If the projection is to be started at a definite time take care to defrost the glass in advance so that the LEDs can be lit at the time required In caso di proiezioni temporizzate da iniziare ad orari definiti si consiglia di alimentare il proiettore con sufficiente anticipo per permettere lo sbrinamento del ...

Reviews: