Important Safeguards - Indoor Use

 
GRAPHIC SYMBOL EXPLANATION 

The lightning bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric shock. 

 

The exclamation point symbol alerts the user to the presence 

of important operating and maintenance instructions. 

 

WARNING 

To reduce a risk of fire or electric shock, do 
not expose this product to rain or moisture. 

 

1. Read Instructions -

 Read all safety and operating 

instructions before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol 

cleaners) 

 

a) 

For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

6. Attachments -

 Use only UL Listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for 

outdoor environments where they will be exposed to water or 

moisture. 

8. Accessories -

 Do not place the unit on an unstable surface 

to avoid falling. Use only UL Listed Vicon recommended mounting 

accessories. 

9. Ventilation -

 Do not block ventilating slots and openings as 

they ensure reliable operation. Do not place the unit near a 

heat source or into an enclosure unless recommended by 

Vicon. 

10. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power outlet. 

Contact an electrician to replace an obsolete outlet. Do not 

force a plug into a non-grounded outlet. 

11. Power Cord Protection -

 Power supply cords should not 

be routed in trafficked areas or in tight spaces where they will 

be pinched or used to bear weight. Allow some slack in the 

cord where it enters the unit. 

12. Lightning -

 Disconnect the product from its power source 

and cable system when possible to prevent damage due to 

lightning and power-line surges. 

13. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Contact 

with power lines can be fatal. 

14. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

15. Object and Liquid Entry -

 Never probe through, or spill 

liquid into, enclosure openings to prevent risk of fire or electric 

shock. 

16. Servicing -

 Refer all servicing to qualified service 

personnel. 

17. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b)  Objects have fallen or liquid has been spilled into the 

product. 

c) 

The product is not designed for outdoor use and has been 
exposed to water or moisture. 

d)  The product does not operate per the operating 

instructions. Perform Vicon recommended adjustments, 
modifications and troubleshooting only to avoid unit 
damage and personal injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in performance. 

 

18. Replacement Parts -

 Use only Vicon specified 

replacement parts or an approved equivalent to prevent unit 

damage and injury. 

19. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

20. ESD Precaution -

 Take all normal electrostatic discharge 

precautions to avoid component damage during installation and 

operation. 

21. For 230 VAC Devices Only -

 When the disconnect device 

is not incorporated in the equipment or when the plug on the 

power supply is intended to serve as the disconnect device, 

follow the guidelines below: 

a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into 

the site wiring. 

b) 

For 230 VAC units with a plug, the outlet must be installed 

near the unit and be easily accessible. 

 
 

 

Summary of Contents for V894CSH

Page 1: ...specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Loctite is a trademark of Loctite Corporation VICON INDUSTRIES INC 89 ARKAY DRIVE H...

Page 2: ......

Page 3: ...be determined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment...

Page 4: ...ing the Housing 4 Cable Connections 4 Camera Lens Adjustments 5 Camera Settings 5 Lens Autoiris Adjustment 11 Camera Positioning 11 Final Installation Steps 12 Maintenance 12 Shipping Instructions 12...

Page 5: ...tight spaces where they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when po...

Page 6: ......

Page 7: ...ate plastic window Each unit is equipped with a high resolution color camera with an isolated power input and an autoiris varifocal lens Refer to Table 1 for a list of model descriptions The V894CSH s...

Page 8: ...e arrangements for a representative of the carrier to inspect the damaged equipment If the equipment must be returned for repair follow the Shipping Instructions at the end of this document Physical I...

Page 9: ...Supplied as spares Cable tie mount adhesive base 3 Secures camera power cables Cable tie 3 Secures camera power cables Video focus adjustment cable for connection to portable local monitor 1 Video fo...

Page 10: ...ing mounted on a sheet metal surface use rivet nuts 4 The cable access hole in the housing accommodates standard cable access fittings as used with electrical junction boxes If such a fitting is not t...

Page 11: ...the menus on the PC monitor Use the cable included in the accessory kit to connect the spot monitor Refer to Figure 6 Pressing the joystick down Center accesses the menu mode and confirms settings Pus...

Page 12: ...DE SYNC MODE R Y GAIN V_PHASE B Y GAIN D N MODE CAMERA ID C SUP TITLE A SUP DPC MONITOR LANGUAGE BAUDRATE OMNI LENS MIRROR EXIT SHARPNESS SAVE EXIT GAMMA FACTORY SET FREEZE NEGA 3D_DNR D_ZOOM SLC HME...

Page 13: ...dynamic range can be turned ON or OFF default With Max DR ON the picture adjusts when there are differing light levels in the image The level can be adjusted from 1 20 AGC Automatic Gain Control can...

Page 14: ...0 the higher the number the more reduction Function The Function menu has settings for Mirror Sharpness Gamma Freeze Nega negative 3D DNR Digital Noise Reduction Digital Zoom SLC Side Light Compensati...

Page 15: ...set to ON the Set Window screen displays to show the 240 areas Individual areas can be selected for motion detection To exit this screen navigate to any outermost corner of the screen All Set All Cle...

Page 16: ...ntifier The camera ID is a user selectable title for the camera that is up to 16 characters default is 0 Title The camera title ID display can be turned ON or OFF default If turned ON the title can be...

Page 17: ...en adjusting the focus it is recommended that the iris be completely open a dark condition either at night or using a filter so that the depth of field does not influence the adjustment On autoiris le...

Page 18: ...es no maintenance except the occasional cleaning of the housing and window Use a soft cloth and plain soap and water Do not use abrasive cleansers that can scratch the window surface or the finish on...

Page 19: ...DC resistance The larger cable results in a lower DC resistance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance prov...

Page 20: ...1068 326 18 1707 520 16 2712 827 14 4307 1312 12 6859 2091 Connectors Power 2 pin screw terminal block Video BNC on pendant cable Certifications FCC Class A CE OPERATIONAL Control Display On screen me...

Page 21: ...stic Finish Satin brushed Closure Cover secured in place by tamperproof screws Housing Mounting Designed to mount into 90 corner Four mounting holes 0 22 in 5 6 mm are provided Mounting hardware inacc...

Page 22: ...able Video Output Composite video 1 0 V p p Composite video 1 0 V p p BLC ON OFF OSD menu selectable ON OFF OSD menu selectable AGC Low Middle High OFF OSD menu selectable ON OFF OSD menu selectable F...

Page 23: ...ance with policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may...

Page 24: ...quarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5...

Reviews: