2200004
_7225
2018 04 20
English
EN
Grapple module installation
Perform installation in reverse order.
See tightening torque table
.
Connection
In order for the grapple module to function correctly,
attachment must take place as illustrated.
See Figure below.
Model
Tightening torque
G400B
130
Nm
G600B,RG600
330 Nm
G800B, RG800
330 Nm
G850B, RG850
330 Nm
G910, RG900
600 Nm
G1060, RG1050
600 Nm
Danger!
In the case of incorrect connection,
gripping force may be lost and the load
dropped.
Dropping a load may result in damage to
property and the risk of personal injury or
serious personal injury.