22
ENGLISH
4
Scope of delivery
Variante 1:
Variante 2:
Variante 3:
R600 VarioClean basic
R600 VarioClean basic
R600 VarioClean basic
Guide tube
Guide tube
Guide tube
Operating manual
Operating manual
Operating manual
Battery and charger in a case
Battery and charger in a case
Tool case
5
Function of the Unit
Optional:
The device can also be carried by the carrying strap, which is available as an accessory, when it
has to be transported. Attach this by hooking the hooks on the carrying strap in the eyelets.
When you use a carrying strap, the device must only be worn across your chest or
your back and it must NEVER be worn around your neck!
It should only be carried without the spiral or tools!
The strap must be completely removed before starting any work to prevent acci-
dents!
5.1
Overview
(A)
1
Battery
6
On / Off button
2
Control panel / Controller
7
Guide tube
3
Lights
8
Carrying strap
4
Spiral
9
Tripod holder
5
Clamping lever
5.2
Changing the battery
(B1)
Slide the battery in up to the stop. Pull the battery out to remove it.
5.3
Controller
(B2)
Controller:
Counter-clockwise
rotation
Releases the
spiral
Clockwise rotation
Clears the blockage
Speed Level 1
Unblocking
Speed Level 2
Cleaning
Speed Level 3
Spins for cleaning
If you press down on the button, all of the LEDs will light up for 3 seconds (controller active) and
so will the two LEDs in the housing.
Attention! Do not look directly into the LEDs in the housing. Danger of being dazzled!
The controller will switch off automatically and all of the LEDs will go out if no other switch is
pressed within 5 minutes.
5.4
Fitting a standard spiral
(C)
Attention! Only use correct spirals!
The spiral diameters and spiral lengths that can be used are listed in the technical data.
The spirals can be connected to one another by using a coupling and divided back into sections
again using a separating key; do this by inserting the separating key in the hole in the coupling
and then pull the coupling apart sideways.