Permanent time programs
Time programs control the heating circuit temperatures or the op-
erating times of the circulation pump according to the specified
switching cycles for the connected heating circuits and the
storage charging circuit. The switching cycles are saved in time
blocks for which different target temperatures can be set.
In the switching cycles, the heating system is controlled differ-
ently according to
day
and
reducing mode
.
The target temperatures for these time programs are set in the
rotary switch positions
"Set Temp Day"
,
"Set Temp Night"
and
"DHW Set Temp"
.
The following switching time programs are available:
–
2 time programs for the heating circuit
, each with 3 possi-
ble switching cycles
– [HC Program 1]
– [HC Program 2]
Tab. 3-8 Menu structure of heating circuit/time program
–
2 time programs for the hot water circuit
, each with 3 pos-
sible switching cycles
– [DHW Program 1]
– [DHW Program 2]
–
1 time program for an optionally connected circulation
pump
, each with 3 possible switching cycles
– [Circulation Time]
Saved switching time programs can be changed at any time. For
a better overview, it is recommended to write down and safely
store the programmed switching cycles (see chap. 9.1.1).
The permanent time programs are preset according to tab. 3-9.
The times can be entered separately for each individual
weekday or in blocks of "Monday to Friday", "Saturday
to Sunday" and "Monday to Sunday".
Program
Time period
Switching cycle
HC Program 1
Individual weekday
(Monday, Tuesday …)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:--
--:-- -> --:--
Working week
(Monday to Friday)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:--
--:-- -> --:--
Weekend
(Saturday to Sunday)
1.
2.
3.
07:00 -> 23:00
--:-- -> --:--
--:-- -> --:--
Whole week
(Monday to Sunday)
1.
2.
3.
06:00 -> 22:00
--:-- -> --:--
--:-- -> --:--
HC Program 2
See
HC Program 1
1.
2.
3.
See
HC Program 1
Time settings for a switching cycle in a weekday or
block program will also be accepted for other time pe-
riods as long as they are for the same weekdays. Ex-
amples referring to tab. 3-8:
a) The starting time in the 1st switching cycle is changed from
06:00 am to 05:00 am for the individual weekday "Monday".
The 1st switching cycle is also automatically changed
from 06:00 am to 05:00 am for the "working week" and
"whole week" time periods.
b) The starting time in the 1st switching cycle is changed from
07:00 am to 08:00 am for the "weekend" time period.
The 1st switching cycle is also automatically changed
from 07:00 am to 08:00 am for the individual weekdays
"Saturday" and "Sunday".
c) The end time in the 1st switching cycle is changed from
10:00 pm to 9:30 pm for the "whole week" time period.
The 1st switching cycle is also automatically changed
from 10:00 pm to 9:30 pm in all weekday or block pro-
grams.
The setting and the entry structure of the time programs
are identical with those for the heating circuit time
program (see also tab. 3-8).
The setting and the entry structure of the time program
are identical with those for the heating circuit time pro-
gram (see also tab. 3-8).
For further information on settings for an optional circulation
pump, see chap. 3.6.15.