EbV
Product documentation THETA NORM/UNIT
5-34
5.4.4.3.2
Separate Control Mode Nighttime Temperature
Function:
In this operating mode, the relevant setpoint applies only to the selected HC (=
unmixed circuit), MC 1 (= mixed circuit 1) or MC 2 (= mixed circuit 2)
Setting:
• Press
¦
key
• Select the desired heating circuit, HC, MC-1 or MC-2, using the rotary pushbutton
• Confirm the selected circuit by pressing the rotary pushbutton
• Set the flashing room temperature value by turning the rotary pushbutton to the
desired value.
• Confirm set value by pressing
¦
or
î
, press again: return to standard
display
• Alternatively the value can be confirmed by automatic exit after the set time.
5.4.4.3.3
Separate Control Mode Operating Mode Selection
Function:
In separate operating mode, the selected program only applies to the previously
specified heating circuit.
Hence each heating circuit can be assigned its own operating mode.
Setting:
• Press
¢
key
• Select the desired heating circuit, HC, MC-1, MC-2 or DHW using the rotary
pushbutton
• Confirm the selected circuit by pressing the rotary pushbutton
• Set the flashing operating mode by turning the rotary pushbutton to the desired
value.
• Confirm set value by pressing
¢
or
î
.
• In short-term operating modes (Holiday, Absence, Party) set the desired target
value by turning the rotary pushbutton and confirm the set value as described
above.
• Alternatively the value can be confirmed by automatic exit after the set time.
¦
ROOM NIGHT
HC
16.0
o
c
OP. MODE
MC1
AUTOMATIC
MC1
Summary of Contents for Controller Series
Page 2: ......
Page 8: ...EbV Product documentation THETA NORM UNIT VI...
Page 10: ...EbV Product documentation THETA NORM UNIT 1 2...
Page 16: ...EbV Product documentation THETA NORM UNIT 2 6...
Page 18: ...EbV Product documentation THETA NORM UNIT 3 2...
Page 20: ...EbV Product documentation THETA NORM UNIT 4 2...
Page 70: ...EbV Product documentation THETA NORM UNIT 5 50...
Page 78: ...EbV Product documentation THETA NORM UNIT 6 8...
Page 162: ...EbV Product documentation THETA NORM UNIT 10 10...
Page 170: ...EbV Product documentation THETA NORM UNIT 11 8...