EbV
Product documentation THETA NORM/UNIT
5-4
Setting:
Press the
§
key
Set the flashing specified domestic hot water temperature by turning the
rotary pushbutton
î
to the desired value.
Confirm the set value by pressing either the
§
key or the rotary
pushbutton
î
.
Alternatively: the value can be acquired automatically after the set INFO
TIME
Factory setting
50 °C
Setting range:
Hot water economy temperature ... water heater maximum temperature
limit (service setting)
Single DHW Charging Function
Pushing the
§
key for approx. 3 s will lead to the charging function, in which the
charging time is set in min. If a charging time of 0 min is set, the charging function is
started and the DHW-tank is charged up to the DHW setpoint. The time interval for
the overlapping DHW charging mode can be adjusted between 0 and 240 min. The
current weekly program is overlapped.
5.1.2.5
"Operating Mode" Key (Basic Display)
Sets the operating mode and jumps back to the basic display from any control level.
The operating mode appears in plain text, while at the same time a cursor at the
bottom of the display indicates the relevant operating mode symbol. In control
mode 1 the set point is identical for all the heating circuits. In control mode 2 the
setpoint is individual for the circuits concerned.
The following operating modes can be selected:
Overview of the Operating Modes
Arrow on the
Symbol
Operating mode
Basic Display
Individual setting
æ
Holiday
Return Date
ç
Absent
P1(2,3), Return
time
è
Party
P1(2,3), Party End
Time
é
Automatic
P1(2,3)
DHW
DAY
o
c
50.0
1 TIME DHW
min
0.0
¢
HOLIDAY TIL
19.27
24:09
ABSENT TIL
14.27
19:27
PARTY TIL
19.27
00:27
Su 27.AUG."00
19.27
o
c
58.5
Summary of Contents for Controller Series
Page 2: ......
Page 8: ...EbV Product documentation THETA NORM UNIT VI...
Page 10: ...EbV Product documentation THETA NORM UNIT 1 2...
Page 16: ...EbV Product documentation THETA NORM UNIT 2 6...
Page 18: ...EbV Product documentation THETA NORM UNIT 3 2...
Page 20: ...EbV Product documentation THETA NORM UNIT 4 2...
Page 70: ...EbV Product documentation THETA NORM UNIT 5 50...
Page 78: ...EbV Product documentation THETA NORM UNIT 6 8...
Page 162: ...EbV Product documentation THETA NORM UNIT 10 10...
Page 170: ...EbV Product documentation THETA NORM UNIT 11 8...