Exceeding over
160 °C (320 °F)
Table 4.
Excess temperature over 160 °C (320 °F) for longer than 15 min.
Step
Procedure
1
The whole engine must be inspected, repaired or overhauled in accordance
with the BRP-Powertrain instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components.
4
Inspect the whole oil system (oil cooler, oil lines) must be inspected.
5
Cut oil filter housing and inspect filter mat for foreign matter.