d0
45
27.
fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 914 Series
Edition 2 / Rev. 0
05-50-00
page 22
January 01/2010
3.12) Periodic rise and fall in boost pressure and speed (vibration of
turbo control unit)
General note
WARNUNG
WARNING
Danger of serious injury!
The engine must not be put into operation until the
cause has been ascertained and the fault remedied.
WARNUNG
NOTICE
If the permissible operating limits are exceeded or val-
ues fall below the minimum, the corresponding checks
must be also be carried out.
Periodic rise and fall in boost pressure and speed
Step
Procedure
1
Visual inspection of the engine, in particular
-
Turbocharger
-
Air intake system
2
Check wiring. See 12-20-00 section:
.
NOTE:
If no mechanical damage is detected during the visual in-
spection, check the boost pressure control.
See chap. 76-00-00 of the Heavy Maintenance Manual
Summary of Contents for 914 series
Page 183: ......