m
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 914 Series
Edition 2 / Rev. 0
12-20-00
page 47
January 01/2010
12.4) Checking of the float chamber
General note
.
Instruction
To check of the float chamber the following steps are necessary:
WARNUNG
WARNING
Risk of Burns!
Hot engine parts!
Always allow engine to cool down to ambient tempera-
ture before start of any work.
Step
Procedure
1
Remove drip tray (1).
2
Open attachment screw (2).
3
Remove float chamber (3) with gasket (4) and both floats.
4
Remove both floats (5) from the float chamber.
5
Inspect the float chamber for contamination and corrosion.
WARNUNG
NOTICE
If any contamination on float chamber the find out what
the cause is and take corresponding action to rectify
the problem. Inspect and clean the complete fuel sys-
tem including carburetor.
Step
Procedure
6
Assembly of the float chamber should be carried out analogously the disas-
sembly.
7
Adjust with the idle speed adjustment.
See chap. 12-20-00 section: