Technical Specifications
AY-Dx9M Family Installation and Programming Manual
9
2.
Technical Specifications
Electrical
Characteristics
AY-D09M
AY-D19M
Power Supply Type
Linear type (recommended)
Operating Voltage Range
5–16 VDC
Maximum Input Current
(not including attached
devices)
Standby: 55 mA
Max: 100 mA
Card Read Distance*
N/A
80 mm (3.0 in.)
Proximity Card Modulation
N/A
•
Wiegand 26-Bit, ASK
at 125 kHz
•
Clock & Data, ASK at
125 kHz
Proximity Card Compatibility
N/A
All 26-Bit EM cards
Keypad Transmit Format
•
Single Key, Wiegand 6-Bit (Rosslare
Format)
•
Single Key, Wiegand 6-Bit with Nibble
and Parity Bits
•
Single Key, Wiegand 8-Bit, Nibbles
Complemented
•
4 Keys Facility Code, Wiegand
26-Bit
•
1 to 5 Keys + Facility Code, Wiegand
26-Bit
•
6 Keys BCD and Parity Bits, Wiegand
26-Bit
•
Single Key, 3x4 Matrix Keypad
•
1 to 8 Keys BCD, Clock & Data
Tamper
Only with Rosslare controllers AC-015, AC-
020, and AC-115
* Measured using a Rosslare proximity card or equivalent. Range also
depends on electrical environment and proximity to metal
.