Entering Programming Mode
To enter Programming mode:
1.
Press
#
for 2 seconds.
The Mode LED turns off and the
Program LED turns red.
2.
Enter your 4-digit Programming code.
If the Programming code is valid, the
Program LED turns green and the AY-
Dx9M enters Programming mode.
•
The factory default Programming code is 1234.
•
If a Programming code is not entered within 30 seconds, the AY-
Dx9M returns to Transmit mode.
5.2
Exiting Programming Mode
To exit Programming mode at any time:
1.
Press
#
.
You hear a beep.
The Program LED turns off and the
Mode LED turns red.
This indicates that the AY-Dx9M has returned to Transmit mode.
Wrong entries may reset the reader back to Transmit mode.
While in Programming mode, if no key is pressed for 30 seconds,
the AY-Dx9M exits Programming mode and returns to Transmit
mode.
Mode
Prog
Red
Mode
Prog
Green
Mode
Prog
Red