3–8 • Start-up
ACO-4400A User Manual (Iss. 03)
11.
Select “Output” = < Primary >. The channel output switches to the Primary input signal
(Composite Video).
12.
Select “Operational Mode” = < Auto >.
Loss of Power
1.
Turn off the power to one of the mains inlets. The associated fault indication appears in
the display.
2.
Restore power to the mains inlet. The fault indication changes to show that the “fault” is
fixed.
3.
Turn off the power to the other mains inlet. The associated fault indication appears in the
display.
4.
Restore power to the mains inlet. The fault indication changes to show that the “fault” is
fixed.
5.
Turn off the power to both mains inlets. The channel output changes to the Primary input
signal (Composite Video) and the unit powers down.