PIM Site Analyzer
α
Manual
© Rosenberger 2017 -
www.rosenberger.com/pia
Page 41 of 54
11 Technical Specifications
11.1 Base Unit
11.1.1 General
Display
12.1” Touch screen, readable in direct sunlight
Dimensions
410 × 327 × 173 (L×W×H)
Weight
13.4 kg, including Batteries
RF Ports
-
Filter
-
Base Unit
7/16 DIN (F) Test port (4.3/10 DIN on request)
P-SMP interconnect to Filter, N-Type (F) Isolation
User Interface Ports
2×USB, LAN
Power Supply
Battery Powered or external AC Mains supply
Battery Life
120 min (typical use, non-pulsed CW measurement)
Frequency Stability
± 2.5 ppm
11.1.2 PIM Analyzer RF (Base Unit)
IM Order
3
rd
, 5
th
, 7
th
, 9
th
, 11
th
, 13
th
, 15
th
, 17
th
Output Power
26 – 49 dBm
equals 23 – 46 dBm at Testport
Residual PIM
< -125 dBm (> 168 dBc @ 2x +43 dBm)
PIM vs. Distance
-
Accuracy / Resolution
-
Range
0.2 m (typ)
Depends on number of PIM sources and accuracy of ca-
ble velocity factor
Down to -120 dBm PIM, 0 - 150 m
Frequency Range (seamless)
698 … 2700 MHz
Filter Units
Changeable to frequency bands
11.1.3 PIM Analyzer CPRI (SW Option)
Fiber Interface
CPRI up to Rate 7
IM Order
3
rd
, 5
th
,7
th
Carrier types
LTE5, LTE10, LTE20, (LTE15 on request)
PIM Range
-130 dBm noise floor (depends on RRH NF & Bandwidth)