27
GB
RLS1000 - Rosenbauer
b) Battery to light head communication fault – press
(Button 1) off then on – If
problem still persists unplug the light head completely for 2 minutes then replace
plug and retry.
3. THE EXTERNAL BATTERY CHARGER WON’T RECHARGE THE BATTERY
a) Is charger plug inserted all the way? Make sure plug is inserted fully and locking
ring turned clockwise.
b) Has battery been left completely flat for an extended period of time? Contact us
for assistance.
4. THE INTEGRATED CHARGER SHOWS NO LED INDICATION FOR THE CHARGING
PROCESS
a) Supply cable from vehicle is not connected or there is a poor connection – check
supply and connections from the DC power source.
b) Supply voltage is not high enough to trigger the charger to start – check supply
voltage is 12.5 volts DC or higher. Supply cable must be of adequate size to
prevent voltage drop from the supplying battery to the LED worklight charging
lead.
c) The RLS1000 internal battery is not connected – battery has been left too long in
a discharged state, the battery will need replacing.
5. THE INTEGRATED CHARGER LED SHOWS A RAPIDLY FLASHING AMB
This is a fault indication, the charger has timed out after 18 hours because it
can’t recharge the battery – replace the battery.