4.1
Warning: „Cavitation CAV“
Immediate measure:
Decrease the speed or close the pressure outlet.
4.2
Note: „Unable to Achieve Proportioning Rate“
If the set proportioning rate cannot be attained, the following
message appears:
„Unable to achieve proportioning rate!
Reduce proportioning rate or water intake!“
. This can
happen if, on the one hand, the water flow rate is high and the
proportioning rate is set to a high value or if, on the other hand,
the water pressure is too high due to a high power rating.
4.3
Note: „Malfunction direct injection foam
proportioning system“
The message
„DIGIDOS malfunction! Direct-injection foam
proportioner not ready for operation!“
appears if part
of the electronics unit is not ready for operation.
This means that foam operation is NOT possible.
Measure: Check the cables