Reference Manual
00809-0100-4825, Rev BB
August 2005
A-15
Rosemount 248
Table A-7 continued
Code
Options
Extension Length
N003
3-in (76.2 mm)
N006
6-in. (152.4 mm)
Tapered Barstock Thermowell Process Connection, 316L (1.4404)
T25
Thread Mount,
3
/
4
-in. NPT
T27
Thread Mount, 1-in. NPT
F34
Flange Mount, 1
1
/
2
-in. Class 900/1500
F58
Flange Mount, 1-in. Class 150
F60
Flange Mount, 1
1
/
2
-in. Class 150
F62
Flange Mount, 2-in. Class 150
F78
Flange Mount, 1
1
/
2
-in. Class 300
F96
Flange Mount, 1
1
/
2
-in. Class 600
Immersion Length (Lagging length is 0.5-in)
U002
2-in. (50.8 mm)
U003
3-in. (76.2 mm)
Additional Options Available
This data sheet contains a sample of the many temperature assembly options Emerson
Process Management has available. Refer to the following product data sheets or contact a
sales representative for more choices.
• Temperature Sensor and Accessories, Volume 1 (document number 00813-0100-2654)
• Temperature Sensor and Accessories, Volume 2 (document number 00813-0200-2654)
• Temperature Sensor and Accessories, Volume 3 (document number 00813-0301-2654)
U004
4-in. (101.6 mm)
U005
5-in. (127 mm)
U006
6-in. (152.4 mm)
U007
7-in. (177.8 mm)
U008
8-in. (203.2 mm)
U009
9-in. (228.6 mm)
U010
10-in. (254 mm)
U012
12-in. (304.8 mm)
U015
15-in. (381 mm)
U018
18-in. (457.2 mm)
Special Options
C1
Factory Custom Configuration of Alarm and Saturation Levels, Date, Descriptor and Message Field
A1
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: High Alarm
CN
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: Low Alarm
C4
5-Point Calibration (Use option code Q4 to generate a calibration certificate)
Q4
Calibration Certificate (3-Point standard; use option codes C4 with Q4 for a 5-Point Calibration Certificate)
F6
60 Hz line Voltage Filter
Q8
Thermowell Material Certificate
R01
Thermowell External Pressure Test
Typical Model Number:
248H
A
K5
U
2
UR
N003
T25
U004
F6
(1) The Rosemount 248H with CENELEC Type n Component Approval is not approved as a stand alone unit. Additional system certification is required.
Transmitters must be installed such that it is protected to at least the requirements of IP54.
(2) A
1
/
2
-in. thread adapter is used when Enclosure option code B is ordered with Sensor Type option codes UR, UJ, or UK
(3) Only specify this code if the sensor assembly is ordered though a separate model number (from one of the Sensor Product Data Sheets).
(4) Only available with Enclosure option codes N or U.
(5) Consult factory for availability.
(6) Enclosure option code U cannot be used with Sensor Type option codes DR, DJ, or DK.
Table A-8. 248C Configuration Interface
Model
Product Description
248C
(1)
PC-based HART Configuration Software
Code
Communication Hardware Options
0
Software Only (no Modem)
1
Software with 248C HART Interface Box (Serial Interface with Transmitter Power Supply)
2
Software with Serial HART Modem
3
Software with USB (Universal Serial Bus) HART Modem
Typical Model Number: 248C 1
Summary of Contents for 248
Page 2: ......
Page 4: ......
Page 46: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 4 8 ...
Page 64: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 A 18 ...
Page 74: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 B 10 ...
Page 77: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 1 Rosemount 248 NOTES ...
Page 78: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 0 2 NOTES ...
Page 79: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 3 Rosemount 248 NOTES ...