Reference Manual
00809-0100-4825, Rev BB
August 2005
A-13
Rosemount 248
Table A-6 continued
Code
Options
Extension Length
N035
35 mm (1.38-in.)
N080
80 mm (3.15-in.)
N110
110 mm (4.33-in.)
N135
135 mm (5.32-in.)
N150
150 mm (5.90-in.)
Tapered Barstock Thermowell Process Connection, 316L (1.4404)
T08
Thread Mount,
1
/
2
-in. BSPT (R
1
/
2
)
T10
Thread Mount,
3
/
4
-in. BSPT (R
3
/
4
)
T26
Thread Mount,
1
/
2
-in. BSPF (G
1
/
2
)
T28
Thread Mount,
3
/
4
-in. BSPF (G
3
/
4
)
T44
Thread Mount,
1
/
2
-in. NPT
T46
Thread Mount,
3
/
4
-in. NPT
T48
Thread Mount, 1-inch NPT
T90
Thread Mount, M24 x 1.5
T98
Thread Mount, M20 x 1.5
F04
Flange Mount, 1-in. Class 150
F10
Flange Mount, 1
1
/
2
-in. Class 150
F16
Flange Mount, 2-in. Class 150
F28
Flange Mount, 1
1
/
2
-in. Class 300
F46
Flange Mount, 1
1
/
2
-in. Class 600
F64
Flange Mount,
1
/
2
-in. Class 900/1500
D04
Flange Mount, DN 25 PN 16
D10
Flange Mount, DN 25 PN 25/40
D16
Flange Mount, DN 40 PN 16
Additional Options Available
This data sheet contains a sample of the many temperature assembly options Emerson
Process Management has available. Refer to the following product data sheets or contact a
sales representative for more choices.
• Temperature Sensor and Accessories, Volume 1 (document number 00813-0100-2654)
• Temperature Sensor and Accessories, Volume 2 (document number 00813-0200-2654)
• Temperature Sensor and Accessories, Volume 3 (document number 00813-0301-2654)
Immersion Length
U075
75 mm (2.95-in.)
U100
100 mm (3.94-in.)
U150
150 mm (5.91-in.)
U225
225 mm (8.86-in.)
U250
250 mm (9.84-in.)
U300
300 mm (11.8-in.)
Special Options
C1
Factory Custom Configuration of Alarm and Saturation Levels, Date, Descriptor and Message Field
A1
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: High Alarm
CN
Analog Output Levels Compliant with NAMUR-Recommendations, NE43: Low Alarm
C4
5-Point Calibration (Use option code Q4 to generate a calibration certificate)
Q4
Calibration Certificate (3-Point standard; use option codes C4 with Q4 for a 5-Point Calibration Certificate)
F6
60 Hz line Voltage Filter
Q8
Thermowell Material Certificate
R01
Thermowell External Pressure Test
Typical Model Number:
248H
A
I1
A
1
DR
N080
T08
U250
CN
(1) The Rosemount 248H with CENELEC Type n Component Approval is not approved as a stand alone unit. Additional system certification is required.
Transmitters must be installed such that it is protected to at least the requirements of IP54.
(2) Consult factory for availability.
(3) Enclosure option code U cannot be used with Sensor Type option codes DR, DJ, or DK.
(4) An M20 x 1.5 thread adapter is used when Enclosure option code U is ordered with Sensor Type option codes AR, AJ, or AK.
(5) A
1
/
2
-in. thread adapter is used when Enclosure option code B is ordered.
(6) Only specify this code if the sensor assembly is ordered though a separate model number (from one of the Sensor Product Data Sheets).
(7) Only available with Enclosure option codes N or U.
Summary of Contents for 248
Page 2: ......
Page 4: ......
Page 46: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 4 8 ...
Page 64: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 A 18 ...
Page 74: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 B 10 ...
Page 77: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 1 Rosemount 248 NOTES ...
Page 78: ...Reference Manual 00809 0100 4825 Rev BB August 2005 Rosemount 248 0 2 NOTES ...
Page 79: ...Reference Manual 00809 0100 4825 Rev BB August 2005 0 3 Rosemount 248 NOTES ...