Ropox FlexiElectric 30-66-3 Series User Manual, Mounting Instructions Download Page 16

Page 16 

8. 

Mounting of accessories 

 

 

8.1     Mounting the supporting feet 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

8.2     Mounting the covers for the legs 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
8.3     Mounting the press pad for disabled persons 

 

8.1.1

 

Remove  the  adjusting  screw  of 

the leg. 

 

8.1.2 

Fit the foot and the extension to the 

leg with the screws provided and 
tighten the screws.

 

8.2.1

 

Press  the  covers,  consisting 

of  an  inside  and  an  outside 
cover, carefully over the leg. 

 

8.2.2

 

Lift  up  the  upper/outside  cover  and 

press the snap  lock  into  the  hole  of 
the  leg.  It  is  important  to  pull  the 
snap  lock  completely  out  prior  to 
mounting.  Now  press  in  the  snap 
lock to lock it. 

 

8.3.1

 

The press pad for height 

adjustment must be placed in the 
wooden front fascia

.

 It consists 

of a press pad contact and a 150 
cm long cable provided with a 
DIN-plug. 
The press pad and the cable are 
delivered as one unit ready for 
mounting. 
Drill holes as illustrated to suit the 
required position. 

 

 

8.3.2

 

Fit the press pad by pulling the 

cable through the large hole and 
fasten it in the small   holes by 
means of the M6 nuts provided. 

 

Summary of Contents for FlexiElectric 30-66-3 Series

Page 1: ...FlexiElectric 30 66XXX 3 User Manual Mounting Instructions Keep this folder with product at all times PDF 6087 03 04 2019 PA 2004 00634 QR code to mounting video...

Page 2: ...7 9 Mounting the operating unit 14 7 10 Mounting of distance plates 15 7 11 Mounting of covers 15 8 MOUNTING OF ACCESSORIES 15 8 1 Mounting the supporting feet 16 8 2 Mounting the covers for the legs...

Page 3: ...g to the current Machinery EMC and Low Voltage Directives and thus complies with the basic safety requirements See separate CE declaration See page 277 If these table frames are assembled or otherwise...

Page 4: ...el spindle and various plastic components Surface treatment Chromite Powder coating Standard RAL 9010 mat white Max load of frame 150 kg evenly distributed over the entire worktop Power supply 230VAC...

Page 5: ...for electric and plumbing installations Max load 150kg evenly distributed over the worktop up to 300cm in width according to DS EN 12182 Minimum load capacity per screw bolt 40 kg The fitter should a...

Page 6: ...ax 40 cm This will ensure that the flexible feed pipes will always flex in a neat curve close to the wall without kinking A 90 degree valve with a 1 2 exposed thread is recommended The control unit co...

Page 7: ...none of these parts or other items are trapped when frame is operated Trouble shooting No movement Check mains and power connection to control box Check adapter cable with end resistor is connected c...

Page 8: ...profile 7 1 4 Push the motor with fittings onto the spindle If the motor is not parallel with the leg then turn the motor to vertical position see 7 1 7 7 1 3 Push the connecting spindle through the...

Page 9: ...Push the right hand leg into the groove of the bottom side of the aluminium profile and fasten it in a distance of 2 5 cm from the edge of the aluminium 7 1 7 For worktop length 105 300 cm an additio...

Page 10: ...ct height 65 95 cm without worktop adjust the threaded bolt to each leg After mounting turn the threaded bolts up so they are hidden by the leg Mark and drill the holes for fastening Fasten the frame...

Page 11: ...away from the wall the distance from the back of tabletop to the wall MUST still be equal to or less than 0 5 cm 7 4 Mounting the worktop 7 4 2 The standard aluminium profile is 5 cm shorter than the...

Page 12: ...ktop by means of a clamp Press the front fascia fittings forward against the wooden front fascia and fasten with screws from the inside 7 5 Adjusting the worktop support arms 7 5 2 By means of the two...

Page 13: ...ten the screws on the side of the support arm 7 7 1 Furniture fittings are provided with the frame to keep the wooden side fascia up against the worktop 7 8 Mounting the control unit 7 8 1 The 2 speci...

Page 14: ...be fitted in the wooden front fascia It consists of a control switch with a 1 5 m long cable provided with a DIN plug for the control switch Choose the required position in the front fascia and drill...

Page 15: ...the 2 endcaps on standard cover and push over outer leg 7 11 Mounting of covers 7 10 1 In case of skirting boards you can use the 1 cm deep distance plate to pack the frame out from the wall Distance...

Page 16: ...r outside cover and press the snap lock into the hole of the leg It is important to pull the snap lock completely out prior to mounting Now press in the snap lock to lock it 8 3 1 The press pad for he...

Page 17: ...nnecting hot and cold water as well as waste hoses ALWAYS use flexible hoses to enable the frame to move freely within the height adjustment range 65 95 cm The flexible hoses should be fitted so that...

Page 18: ...2 30 67643 8 6 1 Push support arm into aluminium profile and make sure support arm is level with profile Afterwards tighten screws By using this support arm it is possible to mount hotplate or sink cl...

Page 19: ...se connections follow the movement of the frame and that they do not get squeezed The frame is now reset 5 Press UP on the control switch move the frame to top position and check that the movement is...

Page 20: ...65591 009 End cover for basic cover 2 pcs leg Support arm for worktop 60 62 cm 30 67620 Length of worktop 60 104 cm 2 pcs Length of worktop 105 204 cm 4 pcs Length of worktop 205 249 cm 5 pcs Length...

Page 21: ...0VAC incl netcable 250 cm Enclosed with control box 96000598 Adapter cable 98002082 Adapter plug 98002035 End resistor 2 2 K yellow 97702 433 Plate for fitting of Contol box 30 67870 Extension cable 2...

Page 22: ...worktop 105 204 cm 4 pcs Length of worktop 205 254 cm 5 pcs Length of worktop 255 300 cm 7 pcs Support arm for worktop depth 58 62 cm 30 67642 Right side Support arm is placed further out against the...

Page 23: ...200 cm The infrared control is supplied with 96000629 Split cable 1 pc Safety strip 30 69XXX Length X in whole cm 1 pc Smartbox 30 69002 Option for safety stop Flexi 1 pc when two Flexi frames are sit...

Page 24: ...servation ability may get close to the Flexi frame the person operating the Flexi frame must pay sufficient attention in order to prevent dangerous situations Make sure that there is free space above...

Page 25: ...s freely from bottom to top position without problems Resetting the frame Press DOWN on the control switch and move the frame to bottom position Press DOWN once more and keep the switch depressed for...

Page 26: ...is switched on 2 Check cables and plug in connections between control box and motor motors If The control box makes several click sounds the plug in connections are not correct 3 Check cables and plug...

Page 27: ...EC STANDARDS DS EN 12182 2012 Assistive products for functionally disabled persons General requirements and test methods DS EN 14971 2012 Medical devices Application of risk management to medical dev...

Page 28: ...Complaints We refer to our general Terms of sale and delivery on our homepage www ropox com ROPOX A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 75 05 50 E mail info ropox dk www...

Reviews: