background image

2

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

ATTENTION

: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR

CAUTION:   TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead symbol, within an 
equilateral triangle, is intended to alert the user to the 
presence of uninsulated “dangerous voltage” within the 
product’s enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the 
literature accompanying the product.

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING - When using electric products, basic precautions should always be followed, including the following:

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any of the ventilation openings. Install in 

accordance with the manufacturers instructions.

8. Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades with 
one wider than the other. A grounding type plug has two 
blades and a third grounding prong. The wide blade or the 
third prong are provided for your safety. If the provided plug 
does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.

WARNING:

IMPORTANT:

As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying 

the terminals in your plug, proceed as follows:

The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked by the 

letter E or by the safety earth symbol     or coloured GREEN or GREEN-AND-YELLOW.

The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.

THIS APPARATUS MUST BE EARTHED
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE.
GREEN-AND-YELLOW: EARTH, BLUE: NEUTRAL, BROWN: LIVE

For the U.K.

10. Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11. Only use attachments/accessories specified 

by the manufacturer.

12. Unplug this apparatus during lightning storms or when 

unused for long periods of time.

13. Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 
way, such as power-supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

Before using this unit, carefully read the sections entitled “IMPORTANT SAFETY INSTRUCTIONS,”  “USING THE UNIT SAFELY” (p. 3), and 

“IMPORTANT NOTES” (p. 5). These sections provide important information concerning the proper operation of the unit. Additionally, in 

order to feel assured that you have gained a good grasp of every feature of your new unit, read Owner’s Manual in its entirety. This manual 

should be saved and kept on hand as a convenient reference.

Copyright © 2014 ROLAND CORPORATION

All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.

Summary of Contents for Digital Snake S-2416

Page 1: ...Before using the S 2416 ensure that its system program is at the most recent version For information on available upgrades for the system program see the Roland website http proav roland com...

Page 2: ...rrespond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN AND YELLOW must be connected to the terminal in the plug which is marked...

Page 3: ...n top of heat generating equipment or are Damp e g baths washrooms on wet floors or are Exposed to steam or smoke or are Subject to salt exposure or are Exposed to rain or are Dusty or sandy or are Su...

Page 4: ...before moving the unit Before moving the unit disconnect the power plug from the outlet and pull out all cords from external devices Before cleaning the unit disconnect the power plug from the outlet...

Page 5: ...romptly wipe it away using a soft dry cloth Maintenance For everyday cleaning wipe the unit with a soft dry cloth or one that has been slightly dampened with water To remove stubborn dirt use a cloth...

Page 6: ...ing AES EBU INPUT with a Cascade Connection 14 When Using Duplex REAC Lines 15 When Using a Split Connection 15 When Connecting S 2416 Units to One Another 16 Connecting Devices 17 Connecting Input De...

Page 7: ...angles 2 Using the screws 8 removed in step 1 attach the rack mount angles Be sure to use the screws removed from the unit to secure the angles in place Using different screws might cause damage to t...

Page 8: ...tings of REAC devices must be made correctly Making the wrong settings may result in incorrect audio input and output M The unit functions as a REAC master device S The unit functions as a REAC slave...

Page 9: ...connect the word clock source device such as a word clock generator here 75 switch Set this switch to ON when the S 2416 is used as a word clock input terminal WORD CLOCK OUT connector This is the wor...

Page 10: ...is the master of the sync signal ON CLOCK MASTER The S 2416 is the master of the sync signal You set this when syncing to a word clock signal from an external device such as when using AES EBU input...

Page 11: ...failure 1 Turn on the power to equipment connected to INPUT on the S 2416 2 Turn on the POWER switch on the S 2416 The POWER indicators front and rear light up Rear panel This unit is equipped with a...

Page 12: ...terminal plate or other such passive type cable extending connector problems can occur even when length is less than 100 meters Keep the total cable length of the entire chain as short as possible Do...

Page 13: ...the S 2416 you can make a cascade connection using the REAC BACKUP port This section gives an overview of the settings when connecting the V Mixer with a cascade connection to an S 1608 unit V Mixer M...

Page 14: ...ASCADE OUTPUT Set according to the application 4 5 AES EBU INPUT OFF ENABLE 7 SAMPLE RATE ON WORD CLOCK 8 ON NOTE Change the setting of the REAC MODE switch and MODE switch while the S 2416 is powered...

Page 15: ...ection V Mixer Master S 2416 Split S 2416 Slave S 4000D S 2416 settings REAC MODE switch Setting SP Split NOTE Change the setting of the REAC MODE switch while the S 2416 is powered down When a split...

Page 16: ...tch Setting 1 REAC SLAVE MODE OFF CLOCK SLAVE 2 REAC BACKUP MODE OFF BACKUP 6 AES EBU OUTPUT ON 17 24 Audio signals input via INPUT 17 through 24 on the master unit are output from AES EBU OUTPUT on t...

Page 17: ...gh 24 When a condenser microphone or the like is connected and supplying phantom power is required switch it on by remote control Refer to Making Settings for the Input Channels p 19 Preamp gain and p...

Page 18: ...EBU Commercial CD player Digital recorder Speaker processor OUTPUT INPUT OUTPUT OUTPUT Word clock generator IN IN IN IN AES EBU INPUT Settings NOTE The S 2416 has no built in sampling rate converter...

Page 19: ...S 4000RCS to control the S 2416 is not possible In such cases make the settings using the V Mixer Adjusting the Preamp Gain You can adjust the preamp gain on the S 2416 before sending the signal to a...

Page 20: ...Phantom Power You can supply phantom power from the S 2416 when a condenser microphone or other device requiring 48 V of power is connected NOTE Be sure to switch off phantom power when no device req...

Page 21: ...se the CLIP CLEAR ENTER button When you release the CLIP CLEAR ENTER button while the stereo link is on two periods appear in the channel number shown on the numerical display Example When ch 7 and 8...

Page 22: ...from the following Roland website http proav roland com Refer to the User Guide of S 4000RCS for details of operations and system requirements ConnectingaComputertotheREMOTEConnector Make the connecti...

Page 23: ...ntain a resistor The gain has not been set correctly Adjust the preamp gain for the channels p 19 p 22 No sound is input via AES EBU INPUT The unit is not synced to the word clock signal from an exter...

Page 24: ...Equivalent Input Noise Level E I N INPUT jacks 1 24 128 dB Input Gain 65 dBu IHF A typ Network Latency 375 s when using REAC cable only AD to REAC to DA Latency about 1 2 ms 1 Connectors INPUT jacks 1...

Page 25: ...ata Out 3 RxD Data In 4 NC 5 GND 6 5V 7 Short to pin 8 8 Short to pin 7 9 NC Included RS 232C cable Pins INPUT OUTPUT connector XLR balanced XLR unbalanced Connect COLD and GND when connecting XLR unb...

Page 26: ...Appendix 26 Dimensions 465 7 177 482 101 6 337 2 430 328 2 UNIT mm...

Page 27: ...e receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this...

Page 28: ...For EU Countries For China 5 1 0 0 0 3 9 4 1 3 0 3...

Reviews: