Connecting REAC Devices
14
When Also Using AES/EBU INPUT with a Cascade Connection
This gives an overview of the settings when connecting the V-Mixer with a cascade connection to an S-0816 unit.
V-Mixer: Master
S-0816: Slave
S-2416: Slave
Word-clock generator
IN
IN
AES/EBU
Mixer, etc.
AES/EBU INPUT is the audio signals of inputs 25 through 32 on the S-2416.
S-2416 settings
[REAC MODE] switch
Setting
S (Slave)
[MODE] switch
Setting
1
REAC SLAVE MODE
ON
CLOCK MASTER
2
REAC BACKUP MODE
ON
CASCADE
3
CASCADE OUTPUT
Set according to the application
4
5
AES/EBU INPUT
OFF
ENABLE
7
SAMPLE RATE
ON
WORD CLOCK
8
ON
NOTE
Change the setting of the [REAC MODE] switch and [MODE]
switch while the S-2416 is powered down.
V-Mixer settings
Set the REAC mode to FOH A (External Clock) or FOH B (External
Clock).
NOTE
•
Word-clock frequencies that can be used for synchronization are
96, 48, and 44.1 kHz.
•
Some V-Mixer models do not support 96 kHz.
S-0816 settings
Set the [REAC MODE] switch to S (slave).
NOTE
Change the setting of the [REAC MODE] switch while the S-0816
is powered down.
With these connections and settings, the S-2416 adds the 8 inputs
of the S-1608 after the S-2416’s 32 inputs, and sends them to the
V-Mixer.