Connecting REAC Devices
15
When Using Duplex REAC Lines
If the REAC MAIN signal is interrupted, communication automatically switches to REAC BACKUP.
V-Mixer: Master
S-2416: Slave
S-2416 settings
[REAC MODE] switch
Setting
S (Slave)
[MODE] switch
Setting
1
REAC SLAVE MODE
OFF
CLOCK SLAVE
2
REAC BACKUP MODE
OFF
BACKUP
NOTE
Change the setting of the [REAC MODE] switch and [MODE]
switch while the S-2416 is powered down.
When Using a Split Connection
V-Mixer: Master
S-2416: Split
S-2416: Slave
S-4000D
S-2416 settings
[REAC MODE] switch
Setting
SP (Split)
NOTE
•
Change the setting of the [REAC MODE] switch while the S-2416
is powered down.
•
When a split connection is used, incoming audio signals at
INPUT on the S-2416 are not sent to the V-Mixer. They are output
only from OUTPUT (including AES/EBU OUTPUT).
MEMO
•
Inserting a splitter between the REAC master and slave devices
makes it possible to distribute the output from the REAC master
device to multiple REAC split devices.
Devices whose REAC mode is set to Split become receive-only
devices for signals from the REAC master device.