62
4 Adjustment
4
Adjust the ADJUSTING SCREW A until it makes contact
with the PLATE so that the clearance shown in the figure
will be 9.2—10.6 mm. (STANDARD : 9.7 mm)
7
ADJUSTING SCREW A
Contact part
Tighten SCREW B. Make sure that the PLATE is not
tilting.
8
9.2 ~
10.6 mm
SCREW B
PLATE
9
Tighten SCREW C after setting the HEAD CARRIAGE so
that the RESIN part on the HEAD CARRIAGE makes
contact with the PLATE.
SCREW C
10
Try test printing. If there is twisted ribbon or broken ribbon,
readjust 7 by changing the amount.